Treatment of Vagus Nerve Stimulator Pocket Infection without Removal of the Hardware
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F21%3A10425774" target="_blank" >RIV/00064203:_____/21:10425774 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/21:10425774
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=47iWeQaKHe" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=47iWeQaKHe</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14744/epilepsi.2020.48344" target="_blank" >10.14744/epilepsi.2020.48344</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Treatment of Vagus Nerve Stimulator Pocket Infection without Removal of the Hardware
Popis výsledku v původním jazyce
The management of postoperative pocket infections after vagus nerve stimulator implantation is challenging. Most patients present within four weeks after the implantation of the device and Staphylococcus aureus is the most common infecting agent. Standard medical practice involves the complete hardware removal and antibiotics to achieve long-term cure, with the subsequent reimplantation of the device. Attempts to treat these infections without the removal of the hardware led to high infection recurrence rates because of the formation of staphylococcal biofilms on the device. We present a case of vagus nerve stimulator infection treated successfully with a single surgical debridement of the infected wound and six weeks of antibiotic treatment, but without removing the hardware.
Název v anglickém jazyce
Treatment of Vagus Nerve Stimulator Pocket Infection without Removal of the Hardware
Popis výsledku anglicky
The management of postoperative pocket infections after vagus nerve stimulator implantation is challenging. Most patients present within four weeks after the implantation of the device and Staphylococcus aureus is the most common infecting agent. Standard medical practice involves the complete hardware removal and antibiotics to achieve long-term cure, with the subsequent reimplantation of the device. Attempts to treat these infections without the removal of the hardware led to high infection recurrence rates because of the formation of staphylococcal biofilms on the device. We present a case of vagus nerve stimulator infection treated successfully with a single surgical debridement of the infected wound and six weeks of antibiotic treatment, but without removing the hardware.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Epilepsi [online]
ISSN
1300-7157
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
TR - Turecká republika
Počet stran výsledku
4
Strana od-do
62-65
Kód UT WoS článku
000619039700010
EID výsledku v databázi Scopus
—