Postural and respiratory function of the abdominal muscles: A pilot study to measure abdominal wall activity using belt sensors
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F21%3A10426516" target="_blank" >RIV/00064203:_____/21:10426516 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/21:10426516
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=o6-k0jrmrF" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=o6-k0jrmrF</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3233/IES-203212" target="_blank" >10.3233/IES-203212</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Postural and respiratory function of the abdominal muscles: A pilot study to measure abdominal wall activity using belt sensors
Popis výsledku v původním jazyce
BACKGROUND: The abdominal muscles play an important respiratory and stabilization role, and in coordination with other muscles regulate intra-abdominal pressure (IAP) to stabilize the spine. OBJECTIVE: To examine a new, non-invasive method to measure activation of the abdominal wall and compare changes in muscle activation during respiration while breathing under a load, and during instructed breathing. METHODS: Thirty-five healthy individuals completed this observational crossover study. Two capacitive force sensors registered the abdominal wall force during resting breathing stereotype, instructed breathing stereotype and under a load. RESULTS: Mean abdominal wall force increased significantly on both sensors when holding the load compared to resting breathing (Upper Sensor: P< 0.0005, d=-0.46, Lower Sensor: P< 0.0005, d=-0.56). The pressure on both sensors also significantly increased during instructed breathing compared to resting breathing (US: P< 0.0005, d=-0.76, LS: P< 0.0005, d=-0.78). CONCLUSIONS: The use of capacitive force-sensors represent a new, non-invasive method to measure abdominal wall activity. Clinically, belts with capacitive force sensors can be used as a feedback tool to train abdominal wall activation.
Název v anglickém jazyce
Postural and respiratory function of the abdominal muscles: A pilot study to measure abdominal wall activity using belt sensors
Popis výsledku anglicky
BACKGROUND: The abdominal muscles play an important respiratory and stabilization role, and in coordination with other muscles regulate intra-abdominal pressure (IAP) to stabilize the spine. OBJECTIVE: To examine a new, non-invasive method to measure activation of the abdominal wall and compare changes in muscle activation during respiration while breathing under a load, and during instructed breathing. METHODS: Thirty-five healthy individuals completed this observational crossover study. Two capacitive force sensors registered the abdominal wall force during resting breathing stereotype, instructed breathing stereotype and under a load. RESULTS: Mean abdominal wall force increased significantly on both sensors when holding the load compared to resting breathing (Upper Sensor: P< 0.0005, d=-0.46, Lower Sensor: P< 0.0005, d=-0.56). The pressure on both sensors also significantly increased during instructed breathing compared to resting breathing (US: P< 0.0005, d=-0.76, LS: P< 0.0005, d=-0.78). CONCLUSIONS: The use of capacitive force-sensors represent a new, non-invasive method to measure abdominal wall activity. Clinically, belts with capacitive force sensors can be used as a feedback tool to train abdominal wall activation.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Isokinetics and Exercise Science
ISSN
0959-3020
e-ISSN
—
Svazek periodika
29
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
175-184
Kód UT WoS článku
000639475800008
EID výsledku v databázi Scopus
2-s2.0-85104018865