The aorto-left ventricular tunnel from a fetal perspective: original case series and literature review
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F22%3A10436489" target="_blank" >RIV/00064203:_____/22:10436489 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/22:10436489
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=GYWltXfyZ7" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=GYWltXfyZ7</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/pd.6090" target="_blank" >10.1002/pd.6090</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The aorto-left ventricular tunnel from a fetal perspective: original case series and literature review
Popis výsledku v původním jazyce
INTRODUCTION: Aorto-left ventricular tunnel (ALVT) accounts for <0.1% of congenital heart defects. Evidence on the prognosis from a fetal perspective is limited. With this retrospective international case series, we provide information on the outcome of fetuses with ALVT. METHODS: All members of the Association for European Paediatric and Congenital Cardiology's (AEPC) Fetal Working Group and fetal medicine units worldwide were invited for participation. We observed antenatal parameters, neonatal outcome and postnatal follow-up. Additionally, a systematic search of the literature was performed. RESULTS: Twenty fetuses with ALVT were identified in 10 participating centres (2001-2019). Fetal echocardiographic characteristics of ALVT included an increased cardiac-thorax ratio (95%), left-ventricular end-diastolic diameter (90%) and a dysplastic aortic valve (90%). Extracardiac malformations were rare (5%). Eight fetuses died at a median GA of 21+6 weeks (range, 19-24): all showed signs of hydrops prior to 24 weeks or at autopsy. All others (60%, 12/2) were live-born (median GA 38+4, range 37-40), underwent surgery and were alive at last follow up (median 3.2 years, range 0.1-17). The literature reported 22 ALVT fetuses with similar outcome. CONCLUSIONS: In the absence of fetal hydrops, ALVT carries a good prognosis. Fetuses who survive to 24 weeks without hydrops are likely to have a good outcome. This article is protected by copyright. All rights reserved.
Název v anglickém jazyce
The aorto-left ventricular tunnel from a fetal perspective: original case series and literature review
Popis výsledku anglicky
INTRODUCTION: Aorto-left ventricular tunnel (ALVT) accounts for <0.1% of congenital heart defects. Evidence on the prognosis from a fetal perspective is limited. With this retrospective international case series, we provide information on the outcome of fetuses with ALVT. METHODS: All members of the Association for European Paediatric and Congenital Cardiology's (AEPC) Fetal Working Group and fetal medicine units worldwide were invited for participation. We observed antenatal parameters, neonatal outcome and postnatal follow-up. Additionally, a systematic search of the literature was performed. RESULTS: Twenty fetuses with ALVT were identified in 10 participating centres (2001-2019). Fetal echocardiographic characteristics of ALVT included an increased cardiac-thorax ratio (95%), left-ventricular end-diastolic diameter (90%) and a dysplastic aortic valve (90%). Extracardiac malformations were rare (5%). Eight fetuses died at a median GA of 21+6 weeks (range, 19-24): all showed signs of hydrops prior to 24 weeks or at autopsy. All others (60%, 12/2) were live-born (median GA 38+4, range 37-40), underwent surgery and were alive at last follow up (median 3.2 years, range 0.1-17). The literature reported 22 ALVT fetuses with similar outcome. CONCLUSIONS: In the absence of fetal hydrops, ALVT carries a good prognosis. Fetuses who survive to 24 weeks without hydrops are likely to have a good outcome. This article is protected by copyright. All rights reserved.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Prenatal Diagnosis
ISSN
0197-3851
e-ISSN
1097-0223
Svazek periodika
42
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
11
Strana od-do
267-277
Kód UT WoS článku
000745524400001
EID výsledku v databázi Scopus
2-s2.0-85123464189