Thermal quantitative sensory testing as a screening tool for cardiac autonomic neuropathy in patients with diabetes mellitus
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F22%3A10441285" target="_blank" >RIV/00064203:_____/22:10441285 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/22:10441285 RIV/68407700:21460/22:00357657
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=d__pPAHkK8" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=d__pPAHkK8</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/brb3.2506" target="_blank" >10.1002/brb3.2506</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Thermal quantitative sensory testing as a screening tool for cardiac autonomic neuropathy in patients with diabetes mellitus
Popis výsledku v původním jazyce
INTRODUCTION: Electrophysiological diagnosis of cardiac autonomic neuropathy (CAN) is based on the evaluation of cardiovascular autonomic reflex tests (CARTs). CARTs are relatively time consuming and must be performed under standardized conditions. This study aimed to determine whether thermal quantitative sensory testing (TQST) can be used as a screening tool to identify patients with diabetes at a higher risk of CAN. METHODS: Eighty-five patients with diabetes and 49 healthy controls were included in the study. Neurological examination, CARTs, TQST, biochemical analyses, and neuropathy symptom questionnaires were performed. RESULTS: CAN was diagnosed in 46 patients with diabetes (54%). CAN-positive patients with diabetes had significantly higher warm detection thresholds (WDT) and significantly lower cold detection thresholds (CDT) in all tested regions (thenar, tibia, and the dorsum of the foot). CDT on the dorsum < 21.8°C in combination with CDT on the tibia < 23.15°C showed the best diagnostic ability in CAN prediction, with 97.4 % specificity, 60.9% sensitivity, 96.6% positive predictive value, and 67.3% negative predictive value. CONCLUSION: TQST can be used as a screening tool for CAN before CART.
Název v anglickém jazyce
Thermal quantitative sensory testing as a screening tool for cardiac autonomic neuropathy in patients with diabetes mellitus
Popis výsledku anglicky
INTRODUCTION: Electrophysiological diagnosis of cardiac autonomic neuropathy (CAN) is based on the evaluation of cardiovascular autonomic reflex tests (CARTs). CARTs are relatively time consuming and must be performed under standardized conditions. This study aimed to determine whether thermal quantitative sensory testing (TQST) can be used as a screening tool to identify patients with diabetes at a higher risk of CAN. METHODS: Eighty-five patients with diabetes and 49 healthy controls were included in the study. Neurological examination, CARTs, TQST, biochemical analyses, and neuropathy symptom questionnaires were performed. RESULTS: CAN was diagnosed in 46 patients with diabetes (54%). CAN-positive patients with diabetes had significantly higher warm detection thresholds (WDT) and significantly lower cold detection thresholds (CDT) in all tested regions (thenar, tibia, and the dorsum of the foot). CDT on the dorsum < 21.8°C in combination with CDT on the tibia < 23.15°C showed the best diagnostic ability in CAN prediction, with 97.4 % specificity, 60.9% sensitivity, 96.6% positive predictive value, and 67.3% negative predictive value. CONCLUSION: TQST can be used as a screening tool for CAN before CART.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Brain and Behavior [online]
ISSN
2162-3279
e-ISSN
—
Svazek periodika
12
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
e2506
Kód UT WoS článku
000760599200001
EID výsledku v databázi Scopus
2-s2.0-85125189088