Linear, High Dynamic Range Isolated Skin Resistance Transducer Circuit for Neurophysiological Research in Individuals after Spinal Cord Injury
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F22%3A10442997" target="_blank" >RIV/00064203:_____/22:10442997 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/22:10442997 RIV/68407700:21460/22:00357625
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=WB00iy2uoM" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=WB00iy2uoM</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/electronics11071121" target="_blank" >10.3390/electronics11071121</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Linear, High Dynamic Range Isolated Skin Resistance Transducer Circuit for Neurophysiological Research in Individuals after Spinal Cord Injury
Popis výsledku v původním jazyce
The quantification of skin resistance in individuals after spinal cord injury for the purpose of neurophysiological research is difficult, mainly as a consequence of decreased activity of sweat glands in the injured human organism. In this original work, we propose a custom electrical skin resistance transducer, featuring extremely low patient auxiliary current, linear response and high dynamic range. After the design and fabrication of the prototype device, we conducted preliminary benchmark tests. We found that our prototype transducer was able to linearly report a broad range of resistance presented to its input terminals, which is not usually found in skin resistance research instrumentation. The basic design idea is viable and, following further research, an improved version of presented prototype device may be used for the purpose of neurophysiological research in individuals after spinal cord injury.
Název v anglickém jazyce
Linear, High Dynamic Range Isolated Skin Resistance Transducer Circuit for Neurophysiological Research in Individuals after Spinal Cord Injury
Popis výsledku anglicky
The quantification of skin resistance in individuals after spinal cord injury for the purpose of neurophysiological research is difficult, mainly as a consequence of decreased activity of sweat glands in the injured human organism. In this original work, we propose a custom electrical skin resistance transducer, featuring extremely low patient auxiliary current, linear response and high dynamic range. After the design and fabrication of the prototype device, we conducted preliminary benchmark tests. We found that our prototype transducer was able to linearly report a broad range of resistance presented to its input terminals, which is not usually found in skin resistance research instrumentation. The basic design idea is viable and, following further research, an improved version of presented prototype device may be used for the purpose of neurophysiological research in individuals after spinal cord injury.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30306 - Sport and fitness sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electronics (Switzerland) [online]
ISSN
2079-9292
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
10
Strana od-do
1121
Kód UT WoS článku
000781391000001
EID výsledku v databázi Scopus
2-s2.0-85127392225