Pencil-beam scanning proton therapy for the treatment of glomus jugulare tumours
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F22%3A10445934" target="_blank" >RIV/00064203:_____/22:10445934 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/22:43923781 RIV/00216208:11130/22:10445934 RIV/68407700:21460/22:00365105
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=xufSxTsuva" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=xufSxTsuva</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jmrs.612" target="_blank" >10.1002/jmrs.612</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Pencil-beam scanning proton therapy for the treatment of glomus jugulare tumours
Popis výsledku v původním jazyce
INTRODUCTION: Glomus jugulare tumours (GJT) are benign tumours that arise locally and destructively in the base of the skull and can be successfully treated with radiotherapy. Patients have a long-life expectancy and the late effects of radiotherapy can be serious. Proton radiotherapy reduces doses to critical organs and can reduce late side effects of radiotherapy. The aim of this study was to report feasibility and early clinical results of 12 patients treated using proton therapy. METHODS: Between December 2013 and June 2019, 12 patients (pts) with GJT (median volume 20.4 cm(3) ; range 8.5-41 cm(3) ) were treated with intensity modulated proton therapy (IMPT). Median dose was 54 GyE (Gray Equivalents) (50-60 GyE) with daily fractions of 2 GyE. Twelve patients were analysed with a median follow-up time of 42.2 months (11.3-86.7). Feasibility, dosimetric parameters, acute and late toxicity and local effect on tumour were evaluated in this retrospective study. RESULTS: All patients finished treatment without interruption, with excellent dosimetric parameters and mild acute toxicity. Stabilisation of tumour size was detected on MRI in all patients. No changes in symptoms were observed in comparison with pre-treatment conditions. No late effects of radiotherapy were observed. CONCLUSION: Pencil-beam scanning proton radiotherapy is highly feasible in the treatment of large GJT with mild acute toxicity and promising short-term results. Longer follow-up and larger patient cohorts are required to further identify the role of pencil-beam scanning (PBS) for this indication.
Název v anglickém jazyce
Pencil-beam scanning proton therapy for the treatment of glomus jugulare tumours
Popis výsledku anglicky
INTRODUCTION: Glomus jugulare tumours (GJT) are benign tumours that arise locally and destructively in the base of the skull and can be successfully treated with radiotherapy. Patients have a long-life expectancy and the late effects of radiotherapy can be serious. Proton radiotherapy reduces doses to critical organs and can reduce late side effects of radiotherapy. The aim of this study was to report feasibility and early clinical results of 12 patients treated using proton therapy. METHODS: Between December 2013 and June 2019, 12 patients (pts) with GJT (median volume 20.4 cm(3) ; range 8.5-41 cm(3) ) were treated with intensity modulated proton therapy (IMPT). Median dose was 54 GyE (Gray Equivalents) (50-60 GyE) with daily fractions of 2 GyE. Twelve patients were analysed with a median follow-up time of 42.2 months (11.3-86.7). Feasibility, dosimetric parameters, acute and late toxicity and local effect on tumour were evaluated in this retrospective study. RESULTS: All patients finished treatment without interruption, with excellent dosimetric parameters and mild acute toxicity. Stabilisation of tumour size was detected on MRI in all patients. No changes in symptoms were observed in comparison with pre-treatment conditions. No late effects of radiotherapy were observed. CONCLUSION: Pencil-beam scanning proton radiotherapy is highly feasible in the treatment of large GJT with mild acute toxicity and promising short-term results. Longer follow-up and larger patient cohorts are required to further identify the role of pencil-beam scanning (PBS) for this indication.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30204 - Oncology
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000766" target="_blank" >EF16_019/0000766: Inženýrské aplikace fyziky mikrosvěta</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Medical Radiation Sciences
ISSN
2051-3895
e-ISSN
2051-3909
Svazek periodika
69
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
456-462
Kód UT WoS článku
000840897300001
EID výsledku v databázi Scopus
2-s2.0-85136974805