Complication rates in rigid vs. flexible endoscopic foreign body removal in children
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F23%3A10455612" target="_blank" >RIV/00064203:_____/23:10455612 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/23:10455612
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=UiO0eLkBrX" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=UiO0eLkBrX</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijporl.2023.111474" target="_blank" >10.1016/j.ijporl.2023.111474</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Complication rates in rigid vs. flexible endoscopic foreign body removal in children
Popis výsledku v původním jazyce
While foreign body aspiration remains a frequent and preventable cause of morbidity and mortality in children, recommendations on the appropriate removal technique do often not match the lived practice and expertise of the performing examiners. As there is a scarcity of data regarding success and complication rates of the procedure, the aim of this study was to set up a classification system for procedure-related complications, prospectively record and analyze them. Specialists in the field of foreign body removal contributed cases anonymously. Information regarding procedural details of the bronchoscopy, type, and severity of complications as well as patient characteristics were classified and recorded. Correlations were calculated using Pearson's Chi Square test. A total of 314 rigid and 178 flexible bronchoscopies were compared. Complications were categorized and their severity was defined by the anesthesiologist's assessment of whether to interrupt or terminate the procedure. The overall complication rate was similar in rigid vs. flexible bronchoscopy (19.1% vs. 24.2%, p = 0.232), while respiratory complications occurred significantly less frequent during rigid bronchoscopy (9.2% vs. 16.3%, p = 0.025). This is the largest pediatric case collection recording and comparing complications between rigid and flexible foreign body removal. The higher rate of respiratory complications in flexible bronchoscopy has been shown for the first time and validates some of the concerns about its use for foreign body removal. Flexible bronchoscopy is a safe procedure when extended respiratory monitoring and the possibility of an immediate switch to a secured airway are assured.
Název v anglickém jazyce
Complication rates in rigid vs. flexible endoscopic foreign body removal in children
Popis výsledku anglicky
While foreign body aspiration remains a frequent and preventable cause of morbidity and mortality in children, recommendations on the appropriate removal technique do often not match the lived practice and expertise of the performing examiners. As there is a scarcity of data regarding success and complication rates of the procedure, the aim of this study was to set up a classification system for procedure-related complications, prospectively record and analyze them. Specialists in the field of foreign body removal contributed cases anonymously. Information regarding procedural details of the bronchoscopy, type, and severity of complications as well as patient characteristics were classified and recorded. Correlations were calculated using Pearson's Chi Square test. A total of 314 rigid and 178 flexible bronchoscopies were compared. Complications were categorized and their severity was defined by the anesthesiologist's assessment of whether to interrupt or terminate the procedure. The overall complication rate was similar in rigid vs. flexible bronchoscopy (19.1% vs. 24.2%, p = 0.232), while respiratory complications occurred significantly less frequent during rigid bronchoscopy (9.2% vs. 16.3%, p = 0.025). This is the largest pediatric case collection recording and comparing complications between rigid and flexible foreign body removal. The higher rate of respiratory complications in flexible bronchoscopy has been shown for the first time and validates some of the concerns about its use for foreign body removal. Flexible bronchoscopy is a safe procedure when extended respiratory monitoring and the possibility of an immediate switch to a secured airway are assured.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30209 - Paediatrics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Pediatric Otorhinolaryngology
ISSN
0165-5876
e-ISSN
1872-8464
Svazek periodika
166
Číslo periodika v rámci svazku
March
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
111474
Kód UT WoS článku
000929564900001
EID výsledku v databázi Scopus
2-s2.0-85147584925