Intravenous enoxaparin as alternative ECMO anticoagulation over a period of 94 days: a case report
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F23%3A10458721" target="_blank" >RIV/00064203:_____/23:10458721 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11130/23:10458721
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=gVM-Rh7pgp" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=gVM-Rh7pgp</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s13019-023-02226-0" target="_blank" >10.1186/s13019-023-02226-0</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Intravenous enoxaparin as alternative ECMO anticoagulation over a period of 94 days: a case report
Popis výsledku v původním jazyce
BACKGROUND: Unfractionated heparin is used worldwide as a standard anticoagulation therapy for extracorporeal membrane oxygenation (ECMO) machines. However, its use brings about significant bleeding and thrombotic complications for critically ill patients. This case report shows that low molecular weight heparin together with ECMO-produced primary haemostasis pathology can be used as an alternative way of ECMO anticoagulation. CASE PRESENTATION: This paper presents the case of a patient with respiratory failure who subsequently suffered from cardiac failure and spent 94 days on combined V-V and V-A ECMO devices (two ECMO devices running simultaneously on one patient) with intravenous enoxaparin used instead of unfractionated heparin anticoagulation. No life-threatening bleeding/thrombotic events happened during this period, nor did any technical problems with ECMO occur. CONCLUSIONS: In this case report, continuous intravenous low molecular weight heparin anticoagulation was used as a safe alternative to ECMO anticoagulation.
Název v anglickém jazyce
Intravenous enoxaparin as alternative ECMO anticoagulation over a period of 94 days: a case report
Popis výsledku anglicky
BACKGROUND: Unfractionated heparin is used worldwide as a standard anticoagulation therapy for extracorporeal membrane oxygenation (ECMO) machines. However, its use brings about significant bleeding and thrombotic complications for critically ill patients. This case report shows that low molecular weight heparin together with ECMO-produced primary haemostasis pathology can be used as an alternative way of ECMO anticoagulation. CASE PRESENTATION: This paper presents the case of a patient with respiratory failure who subsequently suffered from cardiac failure and spent 94 days on combined V-V and V-A ECMO devices (two ECMO devices running simultaneously on one patient) with intravenous enoxaparin used instead of unfractionated heparin anticoagulation. No life-threatening bleeding/thrombotic events happened during this period, nor did any technical problems with ECMO occur. CONCLUSIONS: In this case report, continuous intravenous low molecular weight heparin anticoagulation was used as a safe alternative to ECMO anticoagulation.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30223 - Anaesthesiology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Cardiothoracic Surgery
ISSN
1749-8090
e-ISSN
1749-8090
Svazek periodika
18
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
137
Kód UT WoS článku
000967995200012
EID výsledku v databázi Scopus
2-s2.0-85152247565