Optimized prosthetic design, surgical technique, and cosmetic outcome in shoulder reconstruction with double-constrained implant following extra-articular shoulder resection: a proof-of-concept
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F25%3A10498048" target="_blank" >RIV/00064203:_____/25:10498048 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/25:00384903 RIV/00216208:11110/25:10498048
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=xcHZfE99w" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=xcHZfE99w</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s12957-025-03844-9" target="_blank" >10.1186/s12957-025-03844-9</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimized prosthetic design, surgical technique, and cosmetic outcome in shoulder reconstruction with double-constrained implant following extra-articular shoulder resection: a proof-of-concept
Popis výsledku v původním jazyce
Reconstruction of the anatomic defect following extra-articular shoulder resection is a challenging problem, particularly in cases when function of the deltoid muscle and rotator cuff are compromised. Standard reconstruction techniques often result in either instability or rigidity. Constrained implants have been used to overcome these problems; however, they have been associated with a high rate of aseptic loosening. Recently, a novel double-constrained implant has been introduced, yielding promising functional results. Nonetheless, this implant exhibited a cosmetic defect related to protrusion of the humeral component that becomes apparent with time as result of surrounding muscle atrophy. An updated improved design of the implant has been developed to counteract this.We report the case of a 15-year-old patient who underwent an extra-articular (Malawer type V) shoulder resection due to osteosarcoma and received an innovated custom-made double-constrained implant. Moreover, we describe a new modification of the Malawer utilitarian approach to the shoulder girdle that enhances tumor visibility and allows safer dissection. The patient recovered well with satisfactory outcomes at 18 months follow-up, highlighting the potential benefits of this implant design and surgical approach.
Název v anglickém jazyce
Optimized prosthetic design, surgical technique, and cosmetic outcome in shoulder reconstruction with double-constrained implant following extra-articular shoulder resection: a proof-of-concept
Popis výsledku anglicky
Reconstruction of the anatomic defect following extra-articular shoulder resection is a challenging problem, particularly in cases when function of the deltoid muscle and rotator cuff are compromised. Standard reconstruction techniques often result in either instability or rigidity. Constrained implants have been used to overcome these problems; however, they have been associated with a high rate of aseptic loosening. Recently, a novel double-constrained implant has been introduced, yielding promising functional results. Nonetheless, this implant exhibited a cosmetic defect related to protrusion of the humeral component that becomes apparent with time as result of surrounding muscle atrophy. An updated improved design of the implant has been developed to counteract this.We report the case of a 15-year-old patient who underwent an extra-articular (Malawer type V) shoulder resection due to osteosarcoma and received an innovated custom-made double-constrained implant. Moreover, we describe a new modification of the Malawer utilitarian approach to the shoulder girdle that enhances tumor visibility and allows safer dissection. The patient recovered well with satisfactory outcomes at 18 months follow-up, highlighting the potential benefits of this implant design and surgical approach.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30211 - Orthopaedics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
World Journal of Surgical Oncology
ISSN
1477-7819
e-ISSN
1477-7819
Svazek periodika
23
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
194
Kód UT WoS článku
001489906900001
EID výsledku v databázi Scopus
2-s2.0-105005403142