General assembly, diagnosis, imaging: Proceedings of international consensus on orthopedic infections
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00098892%3A_____%2F19%3AN0000006" target="_blank" >RIV/00098892:_____/19:N0000006 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15110/19:73588551
Výsledek na webu
<a href="https://www.arthroplastyjournal.org/article/S0883-5403(18)30852-0/fulltext" target="_blank" >https://www.arthroplastyjournal.org/article/S0883-5403(18)30852-0/fulltext</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
General assembly, diagnosis, imaging: Proceedings of international consensus on orthopedic infections
Popis výsledku v původním jazyce
Findings such as early implant loosening, progressive radiolucent lines, early bone erosions (osteolysis), and periosteal reactions (periostitis) can suggest the presence of PJI, especially in the presence of additional supportive clinical data. However, isolated radiographic findings have limited clinical value due to their low specificity. The literature shows that MRI can be useful in the diagnosis of osteomyelitis in the absence of metal implants, although there are other diagnostic tools that show greater specificity and sensitivity. There is a paucity of data regarding the diagnostic value of MRI for osteomyelitis in the presence of metallic implants. Several techniques for reducing the artifacts seen on MRI exist and others are in development, but there are no clinical data about the diagnostic accuracy of osteomyelitis for MRI in this setting.
Název v anglickém jazyce
General assembly, diagnosis, imaging: Proceedings of international consensus on orthopedic infections
Popis výsledku anglicky
Findings such as early implant loosening, progressive radiolucent lines, early bone erosions (osteolysis), and periosteal reactions (periostitis) can suggest the presence of PJI, especially in the presence of additional supportive clinical data. However, isolated radiographic findings have limited clinical value due to their low specificity. The literature shows that MRI can be useful in the diagnosis of osteomyelitis in the absence of metal implants, although there are other diagnostic tools that show greater specificity and sensitivity. There is a paucity of data regarding the diagnostic value of MRI for osteomyelitis in the presence of metallic implants. Several techniques for reducing the artifacts seen on MRI exist and others are in development, but there are no clinical data about the diagnostic accuracy of osteomyelitis for MRI in this setting.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30211 - Orthopaedics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF ARTHROPLASTY
ISSN
0883-5403
e-ISSN
1532-8406
Svazek periodika
34
Číslo periodika v rámci svazku
2S
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
"S215"-"S223"
Kód UT WoS článku
000455477200026
EID výsledku v databázi Scopus
2-s2.0-85054618124