Quality control in PET/CT and PET/MRI: Results of a survey amongst European countries
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00098892%3A_____%2F22%3A10157803" target="_blank" >RIV/00098892:_____/22:10157803 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S1120179722019780?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S1120179722019780?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ejmp.2022.05.004" target="_blank" >10.1016/j.ejmp.2022.05.004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Quality control in PET/CT and PET/MRI: Results of a survey amongst European countries
Popis výsledku v původním jazyce
Purpose: An EFOMP Working Group (WG) was created in 2020 to establish recommendations for PET/CT/MRI Quality Control (QC). The WG's intention was to create a document containing a set of measurements suitable for routine practice. In order to map the current situation in PET facilities, the WG prepared a survey addressed to European Medical Physics Experts (MPE). Methods: The survey was conducted using an electronic questionnaire with 10 sections, for a total of 43 multiple choice or open questions. Data regarding general information, model of installed scanners, contract of maintenance and phantoms available were collected. The focal part of the questionnaire concerned the QC protocol adopted and accreditation programs. Results: 123 answers from 24 countries were collected. 90.2% of the respondents are affiliated as staff MPEs; 45% have non-digital TOF PET/CT scanners with a contract of maintenance (97.6%). In 98.4% and 86.8% of responding centres a sealed source for daily QC and the NEMA Image Quality Phantom were present. 94.3% of respondents perform daily QC according to manufacturer recommendations, while NEMA Tests are not performed routinely (51.2%). 56.1% of the respondents have scanners accredited by a national or international organization. 56% of the centres perform annual CT tests, while more than 90% do not perform any MRI QCs. Conclusions: The results of the survey show that there is a lack of harmonization in the PET QC procedures across Europe. The information obtained will guide the WG in proposing a guideline containing a set of measurements suitable for the clinical routine.
Název v anglickém jazyce
Quality control in PET/CT and PET/MRI: Results of a survey amongst European countries
Popis výsledku anglicky
Purpose: An EFOMP Working Group (WG) was created in 2020 to establish recommendations for PET/CT/MRI Quality Control (QC). The WG's intention was to create a document containing a set of measurements suitable for routine practice. In order to map the current situation in PET facilities, the WG prepared a survey addressed to European Medical Physics Experts (MPE). Methods: The survey was conducted using an electronic questionnaire with 10 sections, for a total of 43 multiple choice or open questions. Data regarding general information, model of installed scanners, contract of maintenance and phantoms available were collected. The focal part of the questionnaire concerned the QC protocol adopted and accreditation programs. Results: 123 answers from 24 countries were collected. 90.2% of the respondents are affiliated as staff MPEs; 45% have non-digital TOF PET/CT scanners with a contract of maintenance (97.6%). In 98.4% and 86.8% of responding centres a sealed source for daily QC and the NEMA Image Quality Phantom were present. 94.3% of respondents perform daily QC according to manufacturer recommendations, while NEMA Tests are not performed routinely (51.2%). 56.1% of the respondents have scanners accredited by a national or international organization. 56% of the centres perform annual CT tests, while more than 90% do not perform any MRI QCs. Conclusions: The results of the survey show that there is a lack of harmonization in the PET QC procedures across Europe. The information obtained will guide the WG in proposing a guideline containing a set of measurements suitable for the clinical routine.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physica Medica-European Journal of Medical Physics
ISSN
1120-1797
e-ISSN
1724-191X
Svazek periodika
99
Číslo periodika v rámci svazku
July
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
16-21
Kód UT WoS článku
000807743400003
EID výsledku v databázi Scopus
2-s2.0-85130810883