Intravitreal Dexamethasone Implant in the Treatment of Diabetic Macular Edema Focusing on the Role of Oct Biomarkers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00098892%3A_____%2F25%3A10159528" target="_blank" >RIV/00098892:_____/25:10159528 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15110/25:73635433
Výsledek na webu
<a href="https://www.cs-ophthalmology.cz/en/journal/articles/333" target="_blank" >https://www.cs-ophthalmology.cz/en/journal/articles/333</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.31348/2024/29" target="_blank" >10.31348/2024/29</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Intravitreal Dexamethasone Implant in the Treatment of Diabetic Macular Edema Focusing on the Role of Oct Biomarkers
Popis výsledku v původním jazyce
Objective: The aim of this study was to evaluate the outcomes of Ozurdex® (DEX) implant in patients with diabetic macular edema (DME) in real-world clinical practice, and to determine the correlation between known OCT biomarkers and the effect of treatment. Material and Methods: This retrospective study included 42 eyes of 33 patients (16 women, 17 men) treated with DEX at the Department of Ophthalmology, Faculty of Medicine and Dentistry of Palacký University and University Hospital Olomouc for DME indication between 2020 and 2023. Follow-up examinations were conducted at 1, 3, and 6 months after the first DEX application. The main assessed parameters were: best-corrected visual acuity (BCVA), intraocular pressure (IOP), central retinal thickness (CRT), OCT biomarkers. The results were subsequently statistically evaluated. Results: At the first follow-up after DEX application, there was an average decrease in CRT of 186 ±146µm and a gain of 3 ±7 letters. Positive morphological and functional responses were observed in 39 eyes (92.9%) and 23 eyes (54.8%) respectively. The disorganization of retinal inner layers (DRIL) biomarker was initially present in 41 eyes (97.6%), with reduction or disappearance observed in 13 eyes (31%) post-application. Eyes with ellipsoid zone disruption (EZ disruption) had an average initial BCVA of 49.6 letters, compared to 57.8 letters in the group without this biomarker. The mean gain in BCVA was +8.7 letters in treatment-naive eyes and +2.1 letters in previously treated eyes. Chronic DME was less frequent in treatment-naive (n = 1, 14.3%) compared to previously treated eyes (n = 28, 84.8%). All these results were statistically significant (p < 0.05). An increase in IOP post-DEX application occurred in 9 patients (21.4%). Conclusion: Our results confirm DEX as a safe and effective treatment option for DME. Treatment-naive patients achieved better functional outcomes. We confirmed ellipsoid zone disruption (EZ disruption) as a negative biomarker. Additionally, we demonstrated the capacity of DEX to reduce disorganization of the retinal inner layers (DRIL).
Název v anglickém jazyce
Intravitreal Dexamethasone Implant in the Treatment of Diabetic Macular Edema Focusing on the Role of Oct Biomarkers
Popis výsledku anglicky
Objective: The aim of this study was to evaluate the outcomes of Ozurdex® (DEX) implant in patients with diabetic macular edema (DME) in real-world clinical practice, and to determine the correlation between known OCT biomarkers and the effect of treatment. Material and Methods: This retrospective study included 42 eyes of 33 patients (16 women, 17 men) treated with DEX at the Department of Ophthalmology, Faculty of Medicine and Dentistry of Palacký University and University Hospital Olomouc for DME indication between 2020 and 2023. Follow-up examinations were conducted at 1, 3, and 6 months after the first DEX application. The main assessed parameters were: best-corrected visual acuity (BCVA), intraocular pressure (IOP), central retinal thickness (CRT), OCT biomarkers. The results were subsequently statistically evaluated. Results: At the first follow-up after DEX application, there was an average decrease in CRT of 186 ±146µm and a gain of 3 ±7 letters. Positive morphological and functional responses were observed in 39 eyes (92.9%) and 23 eyes (54.8%) respectively. The disorganization of retinal inner layers (DRIL) biomarker was initially present in 41 eyes (97.6%), with reduction or disappearance observed in 13 eyes (31%) post-application. Eyes with ellipsoid zone disruption (EZ disruption) had an average initial BCVA of 49.6 letters, compared to 57.8 letters in the group without this biomarker. The mean gain in BCVA was +8.7 letters in treatment-naive eyes and +2.1 letters in previously treated eyes. Chronic DME was less frequent in treatment-naive (n = 1, 14.3%) compared to previously treated eyes (n = 28, 84.8%). All these results were statistically significant (p < 0.05). An increase in IOP post-DEX application occurred in 9 patients (21.4%). Conclusion: Our results confirm DEX as a safe and effective treatment option for DME. Treatment-naive patients achieved better functional outcomes. We confirmed ellipsoid zone disruption (EZ disruption) as a negative biomarker. Additionally, we demonstrated the capacity of DEX to reduce disorganization of the retinal inner layers (DRIL).
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
30207 - Ophthalmology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Česká a slovenská oftalmologie
ISSN
1211-9059
e-ISSN
1805-4447
Svazek periodika
81
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
16-23
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-105019775330