Real-time Validation of Transcranial Doppler Criteria in Assessing Recanalization During Intra-arterial Procedures for Acute Ischemic Stroke An International, Multicenter Study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F13%3A00060609" target="_blank" >RIV/00159816:_____/13:00060609 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1161/STROKEAHA.112.675074" target="_blank" >http://dx.doi.org/10.1161/STROKEAHA.112.675074</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1161/STROKEAHA.112.675074" target="_blank" >10.1161/STROKEAHA.112.675074</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Real-time Validation of Transcranial Doppler Criteria in Assessing Recanalization During Intra-arterial Procedures for Acute Ischemic Stroke An International, Multicenter Study
Popis výsledku v původním jazyce
Background and Purpose-We sought to evaluate the diagnostic accuracy of ultrasound criteria for recanalization during real-time transcranial Doppler monitoring of intra-arterial reperfusion procedures in acute ischemic stroke patients in an international, multicenter study. Methods-Consecutive acute ischemic stroke patients with proximal intracranial occlusions underwent intra-arterial reperfusion procedures with simultaneous real-time transcranial Doppler monitoring at 3 tertiary-care stroke centers. Residual flow signals at the site of angiographically confirmed occlusions were monitored at a constant transtemporal insonation angle using a standard head-frame. Recanalization was assessed simultaneously by digital subtraction angiography and ultrasound using thrombolysis in myocardial infarction and thrombolysis in brain ischemia (TIBI) criteria, respectively. Independent readers blinded to digital subtraction angiography performed validation of TIBI flow grades. The interrater reliab
Název v anglickém jazyce
Real-time Validation of Transcranial Doppler Criteria in Assessing Recanalization During Intra-arterial Procedures for Acute Ischemic Stroke An International, Multicenter Study
Popis výsledku anglicky
Background and Purpose-We sought to evaluate the diagnostic accuracy of ultrasound criteria for recanalization during real-time transcranial Doppler monitoring of intra-arterial reperfusion procedures in acute ischemic stroke patients in an international, multicenter study. Methods-Consecutive acute ischemic stroke patients with proximal intracranial occlusions underwent intra-arterial reperfusion procedures with simultaneous real-time transcranial Doppler monitoring at 3 tertiary-care stroke centers. Residual flow signals at the site of angiographically confirmed occlusions were monitored at a constant transtemporal insonation angle using a standard head-frame. Recanalization was assessed simultaneously by digital subtraction angiography and ultrasound using thrombolysis in myocardial infarction and thrombolysis in brain ischemia (TIBI) criteria, respectively. Independent readers blinded to digital subtraction angiography performed validation of TIBI flow grades. The interrater reliab
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FH - Neurologie, neurochirurgie, neurovědy
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.100%2F02%2F0123" target="_blank" >ED1.100/02/0123: Fakultní nemocnice u sv. Anny v Brně - Mezinárodní centrum klinického výzkumu (FNUSA - ICRC)</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Stroke
ISSN
0039-2499
e-ISSN
—
Svazek periodika
44
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
394-400
Kód UT WoS článku
000313754800027