Contribution of remote monitoring to the early diagnosis of implantable cardioverter-defibrillator shocks in the patient with cardiac resynchronisation therapy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F13%3A00060799" target="_blank" >RIV/00159816:_____/13:00060799 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.crvasa.2012.12.003" target="_blank" >http://dx.doi.org/10.1016/j.crvasa.2012.12.003</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.crvasa.2012.12.003" target="_blank" >10.1016/j.crvasa.2012.12.003</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Contribution of remote monitoring to the early diagnosis of implantable cardioverter-defibrillator shocks in the patient with cardiac resynchronisation therapy
Popis výsledku v původním jazyce
We present the case of a 68-year-old man with coronary artery disease and a history of recurrent myocardial infarctions, having left ventricular ejection fraction 25% in NYHA functional class III. The patient received a biventricular cardioverter-defibrillator (ICD) Biotronik Lumax 340 HF-T in November 2008 from the primary prophylactic indication. Remote monitoring using the Biotronik Home MonitoringTM (HM) system was activated since device implantation. Up to April 2012 the patient received five shocks including 3 appropriate VF therapies and 2 inappropriate ICD shocks (due to T-wave oversensing and atrial flutter degenerating to VF after ATPs). All arrhythmic events were promptly detected by the HM system with a rapid consequent pharmacological andnon-pharmacological intervention (radiofrequency catheter ablation of atrial arrhythmia and reprogramming the device). This case points out that prophylactic ICD implantation is a justifiable method for the prevention of arrhythmic death
Název v anglickém jazyce
Contribution of remote monitoring to the early diagnosis of implantable cardioverter-defibrillator shocks in the patient with cardiac resynchronisation therapy
Popis výsledku anglicky
We present the case of a 68-year-old man with coronary artery disease and a history of recurrent myocardial infarctions, having left ventricular ejection fraction 25% in NYHA functional class III. The patient received a biventricular cardioverter-defibrillator (ICD) Biotronik Lumax 340 HF-T in November 2008 from the primary prophylactic indication. Remote monitoring using the Biotronik Home MonitoringTM (HM) system was activated since device implantation. Up to April 2012 the patient received five shocks including 3 appropriate VF therapies and 2 inappropriate ICD shocks (due to T-wave oversensing and atrial flutter degenerating to VF after ATPs). All arrhythmic events were promptly detected by the HM system with a rapid consequent pharmacological andnon-pharmacological intervention (radiofrequency catheter ablation of atrial arrhythmia and reprogramming the device). This case points out that prophylactic ICD implantation is a justifiable method for the prevention of arrhythmic death
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.100%2F02%2F0123" target="_blank" >ED1.100/02/0123: Fakultní nemocnice u sv. Anny v Brně - Mezinárodní centrum klinického výzkumu (FNUSA - ICRC)</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cor et Vasa
ISSN
0010-8650
e-ISSN
—
Svazek periodika
55
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
"E281"-"E284"
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—