Design and Validation of a Novel Ferromagnetic Bare Metal Stent Capable of Capturing and Retaining Endothelial Cells
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F14%3A00061154" target="_blank" >RIV/00159816:_____/14:00061154 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s10439-014-1088-3" target="_blank" >http://dx.doi.org/10.1007/s10439-014-1088-3</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10439-014-1088-3" target="_blank" >10.1007/s10439-014-1088-3</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Design and Validation of a Novel Ferromagnetic Bare Metal Stent Capable of Capturing and Retaining Endothelial Cells
Popis výsledku v původním jazyce
Rapid healing of vascular stents is important for avoiding complications associated with stent thrombosis, restenosis, and bleeding related to antiplatelet drugs. Magnetic forces can be used to capture iron-labeled endothelial cells immediately followingstent implantation, thereby promoting healing. This strategy requires the development of a magnetic stent that is biocompatible and functional. We designed a stent from the weakly ferromagnetic 2205 stainless steel using finite element analysis. The final design exhibited a principal strain below the fracture limit of 30% during crimping and expansion. Ten stents were fabricated and validated experimentally for fracture resistance. Another 10 stents magnetized with a neodymium magnet showed a magneticfield in the range of 100-750 mG. The retained magnetism was sufficiently strong to capture magnetically-labeled endothelial cells on the stent surfaces during in vitro studies. Magnetically-labeled endothelial cell capture was also verif
Název v anglickém jazyce
Design and Validation of a Novel Ferromagnetic Bare Metal Stent Capable of Capturing and Retaining Endothelial Cells
Popis výsledku anglicky
Rapid healing of vascular stents is important for avoiding complications associated with stent thrombosis, restenosis, and bleeding related to antiplatelet drugs. Magnetic forces can be used to capture iron-labeled endothelial cells immediately followingstent implantation, thereby promoting healing. This strategy requires the development of a magnetic stent that is biocompatible and functional. We designed a stent from the weakly ferromagnetic 2205 stainless steel using finite element analysis. The final design exhibited a principal strain below the fracture limit of 30% during crimping and expansion. Ten stents were fabricated and validated experimentally for fracture resistance. Another 10 stents magnetized with a neodymium magnet showed a magneticfield in the range of 100-750 mG. The retained magnetism was sufficiently strong to capture magnetically-labeled endothelial cells on the stent surfaces during in vitro studies. Magnetically-labeled endothelial cell capture was also verif
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.100%2F02%2F0123" target="_blank" >ED1.100/02/0123: Fakultní nemocnice u sv. Anny v Brně - Mezinárodní centrum klinického výzkumu (FNUSA - ICRC)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Annals of Biomedical Engineering
ISSN
0090-6964
e-ISSN
—
Svazek periodika
42
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
2416-2424
Kód UT WoS článku
000345394000004
EID výsledku v databázi Scopus
—