CIEF separation, UV detection, and quantification of ampholytic antibiotics and bacteria from different matrices
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F14%3A00061422" target="_blank" >RIV/00159816:_____/14:00061422 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081715:_____/14:00432067 RIV/00216224:14110/14:00073246
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00216-014-8053-8" target="_blank" >http://dx.doi.org/10.1007/s00216-014-8053-8</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00216-014-8053-8" target="_blank" >10.1007/s00216-014-8053-8</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CIEF separation, UV detection, and quantification of ampholytic antibiotics and bacteria from different matrices
Popis výsledku v původním jazyce
The effect of antibiotics on the microbial cells and concentration of antibiotics in the human body is essential for the effective use of antimicrobial therapy. The capillary isoelectric focusing is a suitable technique for the separation and the detection of bacteria, and amphoteric substances from nature. However, the determination of isoelectric points of ampholytic antibiotics by conventional techniques is time consuming. For this reason, capillary isoelectric focusing seems to be appropriate as a simple and reliable way for establishing them. The separation conditions for the capillary isoelectric focusing of selected ampholytic antibiotics with known isoelectric points and pK (a)s, ampicillin (pI 4.9), ciprofloxacin (pI 7.4), ofloxacin (pI 7.1),tetracycline (pI 5.4), tigecycline (pI 9.7), and vancomycin (pI 8.1), were found and optimized in the suitable pH ranges pH 2.0-5.3, 2.0-9.6, and 9.0-10.4. The established values of isoelectric points correspond with those found in the li
Název v anglickém jazyce
CIEF separation, UV detection, and quantification of ampholytic antibiotics and bacteria from different matrices
Popis výsledku anglicky
The effect of antibiotics on the microbial cells and concentration of antibiotics in the human body is essential for the effective use of antimicrobial therapy. The capillary isoelectric focusing is a suitable technique for the separation and the detection of bacteria, and amphoteric substances from nature. However, the determination of isoelectric points of ampholytic antibiotics by conventional techniques is time consuming. For this reason, capillary isoelectric focusing seems to be appropriate as a simple and reliable way for establishing them. The separation conditions for the capillary isoelectric focusing of selected ampholytic antibiotics with known isoelectric points and pK (a)s, ampicillin (pI 4.9), ciprofloxacin (pI 7.4), ofloxacin (pI 7.1),tetracycline (pI 5.4), tigecycline (pI 9.7), and vancomycin (pI 8.1), were found and optimized in the suitable pH ranges pH 2.0-5.3, 2.0-9.6, and 9.0-10.4. The established values of isoelectric points correspond with those found in the li
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical and Bioanalytical Chemistry
ISSN
1618-2642
e-ISSN
—
Svazek periodika
406
Číslo periodika v rámci svazku
25
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
12
Strana od-do
6285-6296
Kód UT WoS článku
000342224300020
EID výsledku v databázi Scopus
—