Letter by Zagatina et al. regarding the article, "Three-dimensional speckle strain echocardiography is more accurate and efficient than 2D strain in the evaluation of left ventricular function"
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F14%3A00061531" target="_blank" >RIV/00159816:_____/14:00061531 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.ijcard.2014.09.186" target="_blank" >http://dx.doi.org/10.1016/j.ijcard.2014.09.186</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijcard.2014.09.186" target="_blank" >10.1016/j.ijcard.2014.09.186</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Letter by Zagatina et al. regarding the article, "Three-dimensional speckle strain echocardiography is more accurate and efficient than 2D strain in the evaluation of left ventricular function"
Popis výsledku v původním jazyce
We read the recently published paper by Xu et al. [1] regarding new and very interesting data of the 3D speckle tracking analysis. The authors have shown the better correlation between3Dspeckletracking and ejection fraction in comparison with the correlation between 2D speckle tracking and ejection fraction measuring by 3D method. After that, they concluded that 3D speckle tracking echocardiography " is more accurate than2D speckle trackingin theevaluation of leftventric- ular function. " We think thisconclusion is not valid; " ejection fraction " and " left ventricular function " are not synonymous. Ejection fraction is one of the parameters that can describe one of the components of left ventricular function - global systolic contraction - this parameter is not exhaustive for the whole ventricular or even systolic function. If theejection fractionwould be theequivalentof the whole left ventricu- lar function, why do we use other parameters, for example, the speckle tracking analysis
Název v anglickém jazyce
Letter by Zagatina et al. regarding the article, "Three-dimensional speckle strain echocardiography is more accurate and efficient than 2D strain in the evaluation of left ventricular function"
Popis výsledku anglicky
We read the recently published paper by Xu et al. [1] regarding new and very interesting data of the 3D speckle tracking analysis. The authors have shown the better correlation between3Dspeckletracking and ejection fraction in comparison with the correlation between 2D speckle tracking and ejection fraction measuring by 3D method. After that, they concluded that 3D speckle tracking echocardiography " is more accurate than2D speckle trackingin theevaluation of leftventric- ular function. " We think thisconclusion is not valid; " ejection fraction " and " left ventricular function " are not synonymous. Ejection fraction is one of the parameters that can describe one of the components of left ventricular function - global systolic contraction - this parameter is not exhaustive for the whole ventricular or even systolic function. If theejection fractionwould be theequivalentof the whole left ventricu- lar function, why do we use other parameters, for example, the speckle tracking analysis
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.100%2F02%2F0123" target="_blank" >ED1.100/02/0123: Fakultní nemocnice u sv. Anny v Brně - Mezinárodní centrum klinického výzkumu (FNUSA - ICRC)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Cardiology
ISSN
0167-5273
e-ISSN
—
Svazek periodika
177
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
IE - Irsko
Počet stran výsledku
1
Strana od-do
634
Kód UT WoS článku
000345232200099