Increased serum urea and creatinine levels correlate with decreased retinal nerve fibre layer thickness in diabetic retinopathy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F15%3A00063392" target="_blank" >RIV/00159816:_____/15:00063392 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.3109/1354750X.2015.1094142" target="_blank" >http://dx.doi.org/10.3109/1354750X.2015.1094142</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3109/1354750X.2015.1094142" target="_blank" >10.3109/1354750X.2015.1094142</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Increased serum urea and creatinine levels correlate with decreased retinal nerve fibre layer thickness in diabetic retinopathy
Popis výsledku v původním jazyce
Correlation of increased levels of serum urea and creatinine with retinal nerve fibre layer (RNFL) thinning on spectral domain optical coherence tomography (SD-OCT) was studied in diabetic retinopathy (DR). Sixty consecutive cases and 20 healthy controlswere included. Cases were divided into three groups: without DR, non-proliferative DR with macular oedema and proliferative DR with oedema. Serum urea and creatinine were measured using a standard protocol. Average (RNFL) was measured using SD-OCT. Increased severity of DR was associated with decrease in levels of serum urea and serum creatinine levels. RNFL thinning correlated positively with increase in serum urea and creatinine levels.
Název v anglickém jazyce
Increased serum urea and creatinine levels correlate with decreased retinal nerve fibre layer thickness in diabetic retinopathy
Popis výsledku anglicky
Correlation of increased levels of serum urea and creatinine with retinal nerve fibre layer (RNFL) thinning on spectral domain optical coherence tomography (SD-OCT) was studied in diabetic retinopathy (DR). Sixty consecutive cases and 20 healthy controlswere included. Cases were divided into three groups: without DR, non-proliferative DR with macular oedema and proliferative DR with oedema. Serum urea and creatinine were measured using a standard protocol. Average (RNFL) was measured using SD-OCT. Increased severity of DR was associated with decrease in levels of serum urea and serum creatinine levels. RNFL thinning correlated positively with increase in serum urea and creatinine levels.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EI - Biotechnologie a bionika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.100%2F02%2F0123" target="_blank" >ED1.100/02/0123: Fakultní nemocnice u sv. Anny v Brně - Mezinárodní centrum klinického výzkumu (FNUSA - ICRC)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomarkers
ISSN
1354-750X
e-ISSN
—
Svazek periodika
20
Číslo periodika v rámci svazku
6-7
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
470-473
Kód UT WoS článku
000365651700015
EID výsledku v databázi Scopus
—