Uncommon Endovascular Technique in Cerebral Venous Sinus Thrombosis Using an Aspiration System - a Case Report
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F16%3A00065386" target="_blank" >RIV/00159816:_____/16:00065386 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/16:00090386
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Uncommon Endovascular Technique in Cerebral Venous Sinus Thrombosis Using an Aspiration System - a Case Report
Popis výsledku v původním jazyce
A patient with ongoing cerebral venous sinus thrombosis and a parieto-occipital intracerebral haematoma was unsuccessfully treated with full-dose intravenous anticoagulation. A common endovascular aspiration technique was indicated because of the progressive severe deterioration, the level of consciousness had failed. As a novel approach, we used the 6F Neuron guiding catheter (together with The Separator 3D) inserted directly into the thrombus instead of the Reperfusion Catheter, for mechanical disruption of the thrombus mass together with continual aspiration. This procedure was safe and successful and can be used in cases of frequent aspiration catheter occlusions by a large amount of thrombus fragments.
Název v anglickém jazyce
Uncommon Endovascular Technique in Cerebral Venous Sinus Thrombosis Using an Aspiration System - a Case Report
Popis výsledku anglicky
A patient with ongoing cerebral venous sinus thrombosis and a parieto-occipital intracerebral haematoma was unsuccessfully treated with full-dose intravenous anticoagulation. A common endovascular aspiration technique was indicated because of the progressive severe deterioration, the level of consciousness had failed. As a novel approach, we used the 6F Neuron guiding catheter (together with The Separator 3D) inserted directly into the thrombus instead of the Reperfusion Catheter, for mechanical disruption of the thrombus mass together with continual aspiration. This procedure was safe and successful and can be used in cases of frequent aspiration catheter occlusions by a large amount of thrombus fragments.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FH - Neurologie, neurochirurgie, neurovědy
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Česká a slovenská neurologie a neurochirurgie
ISSN
1210-7859
e-ISSN
—
Svazek periodika
79
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
3
Strana od-do
219-221
Kód UT WoS článku
000373659400014
EID výsledku v databázi Scopus
—