Threshold for diagnosing hypertension by automated office blood pressure using random sample population data
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F16%3A00065521" target="_blank" >RIV/00159816:_____/16:00065521 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/16:00093336 RIV/00023001:_____/16:00060075 RIV/00064190:_____/16:N0000055 RIV/00216208:11110/16:10327671
Výsledek na webu
<a href="http://dx.doi.org/10.1097/HJH.0000000000001076" target="_blank" >http://dx.doi.org/10.1097/HJH.0000000000001076</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/HJH.0000000000001076" target="_blank" >10.1097/HJH.0000000000001076</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Threshold for diagnosing hypertension by automated office blood pressure using random sample population data
Popis výsledku v původním jazyce
OBJECTIVE: Manual office blood pressure (BP) is still recommended for diagnosing hypertension. However, its predictive value is decreased by errors in measurement technique and the white-coat effect. The errors can be eliminated by automated office BP (AOBP) measurement taking multiple readings with the participant resting quietly alone. Therefore, use of AOBP in clinical practice requires a threshold value for hypertension diagnosis. The aim of the present study was to determine an AOBP threshold corresponding to the 140/90 mmHg manual office BP using data from a large random population sample. METHODS: In 2145 participants (mean age 47.3 +- 11.3 years) randomly selected from a Brno population aged 25-64 years, BP was measured using manual mercury and automated office sphygmomanometers. RESULTS: Manual SBP (mean difference 6.39 +- 9.76 mmHg) and DBP (mean difference 2.50 +- 6.54 mmHg) were higher than the automated BP. According to polynomial regression, automated systole of 131.06 (95% confidence interval 130.43-131.70) and diastole of 85.43 (95% confidence interval 85.03-85.82) corresponded to the manual BP of 140/90 mmHg. Using this cut-off, the white-coat hypertension was present in 24% of participants with elevated manual BP, whereas 10% had masked hypertension and 11% masked uncontrolled hypertension. In individuals with masked uncontrolled hypertension, only AOBP was associated with the urinary albumin-creatinine ratio, whereas there was no association with manual BP. CONCLUSION: AOBP of 131/85 mmHg corresponds to the manual BP of 140/90 mmHg. This value may be used as a threshold for diagnosing hypertension using AOBP. However, outcome-driven studies are required to confirm this threshold.
Název v anglickém jazyce
Threshold for diagnosing hypertension by automated office blood pressure using random sample population data
Popis výsledku anglicky
OBJECTIVE: Manual office blood pressure (BP) is still recommended for diagnosing hypertension. However, its predictive value is decreased by errors in measurement technique and the white-coat effect. The errors can be eliminated by automated office BP (AOBP) measurement taking multiple readings with the participant resting quietly alone. Therefore, use of AOBP in clinical practice requires a threshold value for hypertension diagnosis. The aim of the present study was to determine an AOBP threshold corresponding to the 140/90 mmHg manual office BP using data from a large random population sample. METHODS: In 2145 participants (mean age 47.3 +- 11.3 years) randomly selected from a Brno population aged 25-64 years, BP was measured using manual mercury and automated office sphygmomanometers. RESULTS: Manual SBP (mean difference 6.39 +- 9.76 mmHg) and DBP (mean difference 2.50 +- 6.54 mmHg) were higher than the automated BP. According to polynomial regression, automated systole of 131.06 (95% confidence interval 130.43-131.70) and diastole of 85.43 (95% confidence interval 85.03-85.82) corresponded to the manual BP of 140/90 mmHg. Using this cut-off, the white-coat hypertension was present in 24% of participants with elevated manual BP, whereas 10% had masked hypertension and 11% masked uncontrolled hypertension. In individuals with masked uncontrolled hypertension, only AOBP was associated with the urinary albumin-creatinine ratio, whereas there was no association with manual BP. CONCLUSION: AOBP of 131/85 mmHg corresponds to the manual BP of 140/90 mmHg. This value may be used as a threshold for diagnosing hypertension using AOBP. However, outcome-driven studies are required to confirm this threshold.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Hypertension
ISSN
0263-6352
e-ISSN
—
Svazek periodika
34
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
2180-2186
Kód UT WoS článku
000385536600013
EID výsledku v databázi Scopus
—