Macular hole treated by the inverted internal limiting membrane flap technique: case report
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F16%3A00066881" target="_blank" >RIV/00159816:_____/16:00066881 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/16:00094051
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00717-016-0298-5" target="_blank" >http://dx.doi.org/10.1007/s00717-016-0298-5</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00717-016-0298-5" target="_blank" >10.1007/s00717-016-0298-5</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Macular hole treated by the inverted internal limiting membrane flap technique: case report
Popis výsledku v původním jazyce
Pars plana vitrectomy with peeling of the internal limiting membrane is a standard surgical procedure for an idiopathic macular hole. However, it may not always be associated with a favorable functional and anatomical outcome. Further, with gas tamponade face-down posturing 90 % of the time for at least a week is recommended, which causes the patient discomfort and increases the risk of cataracts. A case of unilateral macular hole in a 74-year-old female patient with initial visual acuity of 0.3 treated by pars plana vitrectomy using an inverted membrane technique is presented. In this method, the internal limiting membrane is peeled off, but a remnant of the membrane attached to the margins of the macular hole is left in place. This membrane flap is then inverted upside-down to cover the macular hole. The facedown position was maintained only overnight. Six days after surgery optical coherence tomography showed a closed macular hole with restoration of the foveal depression and an intact external limiting membrane. Visual acuity improved to 0.5. To increase the percentage of final macular hole-closure it is important to search for new treatment options. An inverted flap technique may support the healing process at the macula and at the same time reduce the need for gas tamponade and postoperative positioning of the patient.
Název v anglickém jazyce
Macular hole treated by the inverted internal limiting membrane flap technique: case report
Popis výsledku anglicky
Pars plana vitrectomy with peeling of the internal limiting membrane is a standard surgical procedure for an idiopathic macular hole. However, it may not always be associated with a favorable functional and anatomical outcome. Further, with gas tamponade face-down posturing 90 % of the time for at least a week is recommended, which causes the patient discomfort and increases the risk of cataracts. A case of unilateral macular hole in a 74-year-old female patient with initial visual acuity of 0.3 treated by pars plana vitrectomy using an inverted membrane technique is presented. In this method, the internal limiting membrane is peeled off, but a remnant of the membrane attached to the margins of the macular hole is left in place. This membrane flap is then inverted upside-down to cover the macular hole. The facedown position was maintained only overnight. Six days after surgery optical coherence tomography showed a closed macular hole with restoration of the foveal depression and an intact external limiting membrane. Visual acuity improved to 0.5. To increase the percentage of final macular hole-closure it is important to search for new treatment options. An inverted flap technique may support the healing process at the macula and at the same time reduce the need for gas tamponade and postoperative positioning of the patient.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FF - ORL, oftalmologie, stomatologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
SPEKTRUM DER AUGENHEILKUNDE
ISSN
0930-4282
e-ISSN
—
Svazek periodika
30
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
4
Strana od-do
138-141
Kód UT WoS článku
000379263600007
EID výsledku v databázi Scopus
—