Single-Phase Versus Multiphase CT Angiography in Middle Cerebral Artery Clot Detection-Benefits for Less Experienced Radiologists and Neurologists
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F17%3A00065820" target="_blank" >RIV/00159816:_____/17:00065820 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/17:00095976
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jstrokecerebrovasdis.2016.08.023" target="_blank" >http://dx.doi.org/10.1016/j.jstrokecerebrovasdis.2016.08.023</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jstrokecerebrovasdis.2016.08.023" target="_blank" >10.1016/j.jstrokecerebrovasdis.2016.08.023</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Single-Phase Versus Multiphase CT Angiography in Middle Cerebral Artery Clot Detection-Benefits for Less Experienced Radiologists and Neurologists
Popis výsledku v původním jazyce
CT angiography (CTA) is recommended as a standard of stroke imaging. We investigated accuracy and precision of standard or single-phase CTA as com- pared with novel technique or multiphase CTA in clot detection in the middle cerebral artery. Methods: Twenty single-phase CTA and twenty multiphase CTA with prevailing M2 occlusion were assessed by 10 radiologists and 10 neurolo- gists blinded to clinical information (7 less experienced and 3 experienced). Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated as compared with reading by two seniors. Reliability was calcu- lated using Krippendorff's alpha (K-alpha). Results: Sensitivity, specificity, PPV, and NPV of single-phase CTA compared with multiphase CTA for M2 clot pres- ence were, respectively, .86, .75, .90, and .67 versus .88, .82, .92, and .72. For secondary or distal clots, sensitivity, specificity, PPV, and NPV of single-phase CTA com- pared with multiphase CTA were .41, .83, .50, and .78 versus .65, .77, .71, and .67. Agreement increased significantly in favor of multiphase CTA for detection of primary clots from moderate (.43) to substantial (.65) in less experienced ra- diologists and from slight (.10) to moderate (.30) in less experienced neurologists. Agreement significantly increased for distal or secondary clot detection in favor of multiphase CTA from fair (.24) to moderate (.49) in experienced radiologists and from slight (.12) to moderate (.46) in experienced neurologists. Conclusions: Multiphase CTA is a reliable imaging tool in M2 clot detection and might rep- resent a beneficial imaging tool in clot detection for less experienced physicians.
Název v anglickém jazyce
Single-Phase Versus Multiphase CT Angiography in Middle Cerebral Artery Clot Detection-Benefits for Less Experienced Radiologists and Neurologists
Popis výsledku anglicky
CT angiography (CTA) is recommended as a standard of stroke imaging. We investigated accuracy and precision of standard or single-phase CTA as com- pared with novel technique or multiphase CTA in clot detection in the middle cerebral artery. Methods: Twenty single-phase CTA and twenty multiphase CTA with prevailing M2 occlusion were assessed by 10 radiologists and 10 neurolo- gists blinded to clinical information (7 less experienced and 3 experienced). Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated as compared with reading by two seniors. Reliability was calcu- lated using Krippendorff's alpha (K-alpha). Results: Sensitivity, specificity, PPV, and NPV of single-phase CTA compared with multiphase CTA for M2 clot pres- ence were, respectively, .86, .75, .90, and .67 versus .88, .82, .92, and .72. For secondary or distal clots, sensitivity, specificity, PPV, and NPV of single-phase CTA com- pared with multiphase CTA were .41, .83, .50, and .78 versus .65, .77, .71, and .67. Agreement increased significantly in favor of multiphase CTA for detection of primary clots from moderate (.43) to substantial (.65) in less experienced ra- diologists and from slight (.10) to moderate (.30) in less experienced neurologists. Agreement significantly increased for distal or secondary clot detection in favor of multiphase CTA from fair (.24) to moderate (.49) in experienced radiologists and from slight (.12) to moderate (.46) in experienced neurologists. Conclusions: Multiphase CTA is a reliable imaging tool in M2 clot detection and might rep- resent a beneficial imaging tool in clot detection for less experienced physicians.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Stroke & Cerebrovascular Diseases
ISSN
1052-3057
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
19-24
Kód UT WoS článku
000396430100013
EID výsledku v databázi Scopus
—