Comparison of radiation exposure, contrast agent consumption and cost effectiveness between computer tomography and 3D rotational angiography of the left atrium to guide catheter ablation in patients with atrial fibrillation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F17%3A00067633" target="_blank" >RIV/00159816:_____/17:00067633 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of radiation exposure, contrast agent consumption and cost effectiveness between computer tomography and 3D rotational angiography of the left atrium to guide catheter ablation in patients with atrial fibrillation
Popis výsledku v původním jazyce
Background. Catheter ablation of complex atrial arrhythmias guided by 3D models of a left atrium (LA) derived from CT/MRI or 3D rotational angiography of the heart (3DRA) is currently a common practice. Our aim is to compare radiation dose, consumption of a contrast agent and cost of these methods. Methods. From 10/2012 to 10/2015, either 3DRA (157 patients using the X-ray system Philips Allura FD 10) or computer tomography (CT) (157 patients using 64-slice CT GE Lightspeed VCT) of the LA was performed in patients undergoing complex atrial arrhythmias ablation. All procedures were monitored for average effective radiation dose, dose of the contrast agent and analysis of a financial expenditures. Results. The average effective radiation dose for 3DRA was 2.11+-0.392 mSv compared to 10.52+-2.093 mSv for CT. The contrast agent consumption was 22.2 mg and 48.2 mg of iodine for 3DRA and CT, respectively. Total price per procedure is 123EUR for 3DRA and 161EUR for CT. Conclusion. Consumption of the contrast agent and radiation burden for LA 3DRA is significantly lower in comparison to most currently used CT scan methods. Cost of both methods is comparable, however, 3DRA is slightly less expensive than CT.
Název v anglickém jazyce
Comparison of radiation exposure, contrast agent consumption and cost effectiveness between computer tomography and 3D rotational angiography of the left atrium to guide catheter ablation in patients with atrial fibrillation
Popis výsledku anglicky
Background. Catheter ablation of complex atrial arrhythmias guided by 3D models of a left atrium (LA) derived from CT/MRI or 3D rotational angiography of the heart (3DRA) is currently a common practice. Our aim is to compare radiation dose, consumption of a contrast agent and cost of these methods. Methods. From 10/2012 to 10/2015, either 3DRA (157 patients using the X-ray system Philips Allura FD 10) or computer tomography (CT) (157 patients using 64-slice CT GE Lightspeed VCT) of the LA was performed in patients undergoing complex atrial arrhythmias ablation. All procedures were monitored for average effective radiation dose, dose of the contrast agent and analysis of a financial expenditures. Results. The average effective radiation dose for 3DRA was 2.11+-0.392 mSv compared to 10.52+-2.093 mSv for CT. The contrast agent consumption was 22.2 mg and 48.2 mg of iodine for 3DRA and CT, respectively. Total price per procedure is 123EUR for 3DRA and 161EUR for CT. Conclusion. Consumption of the contrast agent and radiation burden for LA 3DRA is significantly lower in comparison to most currently used CT scan methods. Cost of both methods is comparable, however, 3DRA is slightly less expensive than CT.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
BIOMEDICAL PAPERS-OLOMOUC
ISSN
1213-8118
e-ISSN
—
Svazek periodika
161
Číslo periodika v rámci svazku
S1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
"S29"-"S34"
Kód UT WoS článku
000428945000006
EID výsledku v databázi Scopus
—