The Attenuation of QRS Power in the Frequency Range 0.05 to 1 kHz
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F17%3A00075908" target="_blank" >RIV/00159816:_____/17:00075908 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.22489/CinC.2017.096-110" target="_blank" >http://dx.doi.org/10.22489/CinC.2017.096-110</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.22489/CinC.2017.096-110" target="_blank" >10.22489/CinC.2017.096-110</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Attenuation of QRS Power in the Frequency Range 0.05 to 1 kHz
Popis výsledku v původním jazyce
The high-frequency QRS (HFQRS) signal was analyzed in four groups of subjects: healthy, patients suffering from coronary artery disease, heart transplanted patients and patients with left bundle branch block (LBBB). Subjects were measured in the supine position with a high-quality ECG system (fs=5 kHz, ADC 24 bits). The dependency of HFQRS power, maximal amplitude and HFQRS width on the passband used was analyzed. Results: The dependency between HFQRS power and frequency in logarithmic scales is nearly linear across all groups. Significant differences exist in HFQRS power attenuation in regard to frequency between groups of subjects, P<0.001. This attenuation is maximal in healthy subjects -48.1 +/- 3.7 [dB per decade], minimal in LBBB -40.2 +/- 2.7. Based on significant differences between healthy and patient groups, we assume that QRS power attenuation may represent new information in ECG analysis. This parameter is independent of the choice of the analyzed frequency band. The dependency of HFQRS shape on frequency is presented by analysis of a healthy subject. Explanation of this significant dependency is a task for the future.
Název v anglickém jazyce
The Attenuation of QRS Power in the Frequency Range 0.05 to 1 kHz
Popis výsledku anglicky
The high-frequency QRS (HFQRS) signal was analyzed in four groups of subjects: healthy, patients suffering from coronary artery disease, heart transplanted patients and patients with left bundle branch block (LBBB). Subjects were measured in the supine position with a high-quality ECG system (fs=5 kHz, ADC 24 bits). The dependency of HFQRS power, maximal amplitude and HFQRS width on the passband used was analyzed. Results: The dependency between HFQRS power and frequency in logarithmic scales is nearly linear across all groups. Significant differences exist in HFQRS power attenuation in regard to frequency between groups of subjects, P<0.001. This attenuation is maximal in healthy subjects -48.1 +/- 3.7 [dB per decade], minimal in LBBB -40.2 +/- 2.7. Based on significant differences between healthy and patient groups, we assume that QRS power attenuation may represent new information in ECG analysis. This parameter is independent of the choice of the analyzed frequency band. The dependency of HFQRS shape on frequency is presented by analysis of a healthy subject. Explanation of this significant dependency is a task for the future.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2017 COMPUTING IN CARDIOLOGY (CINC)
ISBN
—
ISSN
2325-8861
e-ISSN
2325-887X
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
IEEE COMPUTER SOC
Místo vydání
LOS ALAMITOS
Místo konání akce
Rennes
Datum konání akce
24. 9. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000450651100082