Ventricular Electrical Delay Measured From Body Surface ECGs Is Associated With Cardiac Resynchronization Therapy Response in Left Bundle Branch Block Patients From the MADIT-CRT Trial (Multicenter Automatic Defibrillator Implantation-Cardiac Resynchronization Therapy)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F18%3A00069297" target="_blank" >RIV/00159816:_____/18:00069297 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081731:_____/18:00498320
Výsledek na webu
<a href="http://dx.doi.org/10.1161/CIRCEP.117.005719" target="_blank" >http://dx.doi.org/10.1161/CIRCEP.117.005719</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1161/CIRCEP.117.005719" target="_blank" >10.1161/CIRCEP.117.005719</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ventricular Electrical Delay Measured From Body Surface ECGs Is Associated With Cardiac Resynchronization Therapy Response in Left Bundle Branch Block Patients From the MADIT-CRT Trial (Multicenter Automatic Defibrillator Implantation-Cardiac Resynchronization Therapy)
Popis výsledku v původním jazyce
BACKGROUND: Although cardiac resynchronization therapy (CRT) is beneficial in heart failure patients with left bundle branch block, 30% of these patients do not respond to the therapy. Identifying these patients before implantation of the device is one of the current challenges in clinical cardiology. METHODS: We verified the diagnostic contribution and an optimized computerized approach to measuring ventricular electrical activation delay (VED) from body surface 12-lead ECGs. We applied the method to ECGs acquired before implantation (baseline) in the MADIT-CRT trial (Multicenter Automatic Defibrillator Implantation-Cardiac Resynchronization Therapy). VED values were dichotomized using its quartiles, and we tested the association of VED values with the MADIT-CRT primary end point of heart failure or death. Multivariate Cox proportional models were used to estimate the risk of study end points. In addition, the association between VED values and hemodynamic changes after CRT-D implantation was examined using 1-year follow-up echocardiograms. RESULTS: Our results showed that left bundle branch block patients with baseline VED <31.2 ms had a 35% risk of MADIT-CRT end points, whereas patients with VED >= 31.2 ms had a 14% risk (P<0.001). The hazard ratio for predicting primary end points in patients with low VED was 2.34 (95% confidence interval, 1.53-3.57; P<0.001). Higher VED values were also associated with beneficial hemodynamic changes. These strong VED associations were not found in the right bundle branch block and intraventricular conduction delay cohorts of the MADIT-CRT trial. CONCLUSIONS: Left bundle branch block patients with a high baseline VED value benefited most from CRT, whereas left bundle branch block patients with low VED did not show CRT benefits.
Název v anglickém jazyce
Ventricular Electrical Delay Measured From Body Surface ECGs Is Associated With Cardiac Resynchronization Therapy Response in Left Bundle Branch Block Patients From the MADIT-CRT Trial (Multicenter Automatic Defibrillator Implantation-Cardiac Resynchronization Therapy)
Popis výsledku anglicky
BACKGROUND: Although cardiac resynchronization therapy (CRT) is beneficial in heart failure patients with left bundle branch block, 30% of these patients do not respond to the therapy. Identifying these patients before implantation of the device is one of the current challenges in clinical cardiology. METHODS: We verified the diagnostic contribution and an optimized computerized approach to measuring ventricular electrical activation delay (VED) from body surface 12-lead ECGs. We applied the method to ECGs acquired before implantation (baseline) in the MADIT-CRT trial (Multicenter Automatic Defibrillator Implantation-Cardiac Resynchronization Therapy). VED values were dichotomized using its quartiles, and we tested the association of VED values with the MADIT-CRT primary end point of heart failure or death. Multivariate Cox proportional models were used to estimate the risk of study end points. In addition, the association between VED values and hemodynamic changes after CRT-D implantation was examined using 1-year follow-up echocardiograms. RESULTS: Our results showed that left bundle branch block patients with baseline VED <31.2 ms had a 35% risk of MADIT-CRT end points, whereas patients with VED >= 31.2 ms had a 14% risk (P<0.001). The hazard ratio for predicting primary end points in patients with low VED was 2.34 (95% confidence interval, 1.53-3.57; P<0.001). Higher VED values were also associated with beneficial hemodynamic changes. These strong VED associations were not found in the right bundle branch block and intraventricular conduction delay cohorts of the MADIT-CRT trial. CONCLUSIONS: Left bundle branch block patients with a high baseline VED value benefited most from CRT, whereas left bundle branch block patients with low VED did not show CRT benefits.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Circulation-Arrhythmia and Electrophysiology
ISSN
1941-3149
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
—
Kód UT WoS článku
000439150300001
EID výsledku v databázi Scopus
—