Kinetics of platelet adhesion to a fibrinogen-coated surface in whole blood under flow conditions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F21%3A00074560" target="_blank" >RIV/00159816:_____/21:00074560 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/21:00123997
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/10.1002/jcla.23939" target="_blank" >https://onlinelibrary.wiley.com/doi/10.1002/jcla.23939</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jcla.23939" target="_blank" >10.1002/jcla.23939</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Kinetics of platelet adhesion to a fibrinogen-coated surface in whole blood under flow conditions
Popis výsledku v původním jazyce
Aim To test a novel method of assessment of platelet adhesion to a fibrinogen-coated surface in whole blood under flow conditions. Methods We developed a fluidic device that mimics blood flow in vessels. The method of detection of platelet adhesion is based on recording of a scattered laser light signal from a fibrinogen-covered surface. Testing was performed in platelet-rich plasma (PRP) and whole blood of healthy volunteers. Control measurements were performed, followed by tests with inhibition of platelet GPIIa/IIIb and GPIb receptors. Then, the same testing sequence was performed in whole blood of persons with autoimmune thrombocytopenia and type 3 von Willebrand disease. Results The change in intensity of scattered light was 2.7 (2.4; 4.1) times higher in whole blood (0.2 +/- 0.08V, n = 7) than in PRP (0.05 +/- 0.02 V, n = 7), p < 0.01. The blocking of GP IIb/IIIa receptors decreased the intensity of scattered light to 8.5 (6.5;12)%; the blocking of GPIb receptors decreased it to 34 (23;58)%, p < 0.01. In the whole blood of a person with autoimmune thrombocytopenia, the inhibition of GPIb receptors decreased platelet adhesion, but no effect was observed in type 3 von Willebrand disease. Inhibition of platelet GPIIb/IIIa receptors alone or combined inhibition of GPIb and GPIIb/IIIa receptors resulted in almost total suppression of adhesion in both cases. Conclusion Our system effectively registers platelet adhesion to a fibrinogen-coated surface under controlled-flow conditions and may successfully be applied to the investigation of platelet adhesion kinetics.
Název v anglickém jazyce
Kinetics of platelet adhesion to a fibrinogen-coated surface in whole blood under flow conditions
Popis výsledku anglicky
Aim To test a novel method of assessment of platelet adhesion to a fibrinogen-coated surface in whole blood under flow conditions. Methods We developed a fluidic device that mimics blood flow in vessels. The method of detection of platelet adhesion is based on recording of a scattered laser light signal from a fibrinogen-covered surface. Testing was performed in platelet-rich plasma (PRP) and whole blood of healthy volunteers. Control measurements were performed, followed by tests with inhibition of platelet GPIIa/IIIb and GPIb receptors. Then, the same testing sequence was performed in whole blood of persons with autoimmune thrombocytopenia and type 3 von Willebrand disease. Results The change in intensity of scattered light was 2.7 (2.4; 4.1) times higher in whole blood (0.2 +/- 0.08V, n = 7) than in PRP (0.05 +/- 0.02 V, n = 7), p < 0.01. The blocking of GP IIb/IIIa receptors decreased the intensity of scattered light to 8.5 (6.5;12)%; the blocking of GPIb receptors decreased it to 34 (23;58)%, p < 0.01. In the whole blood of a person with autoimmune thrombocytopenia, the inhibition of GPIb receptors decreased platelet adhesion, but no effect was observed in type 3 von Willebrand disease. Inhibition of platelet GPIIb/IIIa receptors alone or combined inhibition of GPIb and GPIIb/IIIa receptors resulted in almost total suppression of adhesion in both cases. Conclusion Our system effectively registers platelet adhesion to a fibrinogen-coated surface under controlled-flow conditions and may successfully be applied to the investigation of platelet adhesion kinetics.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF CLINICAL LABORATORY ANALYSIS
ISSN
0887-8013
e-ISSN
—
Svazek periodika
35
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
—
Kód UT WoS článku
000680966900001
EID výsledku v databázi Scopus
—