Correlation between electromechanical parameters (NOGA XP) and changes of myocardial ischemia in patients with refractory angina
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F21%3A00075150" target="_blank" >RIV/00159816:_____/21:00075150 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.termedia.pl/Correlation-between-electromechanical-parameters-NOGA-XP-and-changes-of-myocardial-ischemia-in-patients-with-refractory-angina,35,45165,1,1.html" target="_blank" >https://www.termedia.pl/Correlation-between-electromechanical-parameters-NOGA-XP-and-changes-of-myocardial-ischemia-in-patients-with-refractory-angina,35,45165,1,1.html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5114/aic.2021.109168" target="_blank" >10.5114/aic.2021.109168</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Correlation between electromechanical parameters (NOGA XP) and changes of myocardial ischemia in patients with refractory angina
Popis výsledku v původním jazyce
Introduction: Cell therapy has the potential to improve symptoms and clinical outcomes in refractory angina (RFA). Further analyses are needed to evaluate factors influencing its therapeutic effectiveness. Aim: Assessment of electromechanical (EM) parameters of the left ventricle (LV) and investigation of correlation between EM parameters of the myocardium and response to CD133+ cell therapy. Material and methods: Thirty patients with RFA (16 active and 14 placebo individuals) enrolled in the REGENT-VSEL trial underwent EM evaluation of the LV with intracardiac mapping system. The following parameters were analyzed: unipolar voltage (UV), bipolar voltage (BV), local linear shortening (LLS). Myocardial ischemia was evaluated with single-photon emission computed tomography (SPECT). The median value of each EM parameter was used for intra-group comparisons. Results: Global EM parameters (UV, BV, LLS) of LV in active and placebo groups were 11.28 mV, 3.58 mV, 11.12%, respectively; 13.00 mV, 3.81 mV, 11.32%, respectively. EM characteristics analyzed at global and segmental levels did not predict response to CD133+ cell therapy in patients with RFA (Global UV, BV and LLS at rest R = -0.06; R = 0.2; R = -0.1 and at stress: R = 0.07, R = 0.09, R = -0.1, respectively; Segmental UV, BV, LLS at rest R = -0.2, R = 0.03, R = -0.4 and at stress R = 0.02, R = 0.2, R = -0.2, respectively). Multiple linear regression of the treated segments showed that only pre-injection SPECT levels were significantly correlated with post-injection SPECT, either at rest or stress (p < 0.05). Conclusions: Electromechanical characteristics of the left ventricle do not predict changes of myocardial perfusion by SPECT after cell therapy. Baseline SPECT results are only predictors of changes of myocardial ischemia observed at 4-month follow-up.
Název v anglickém jazyce
Correlation between electromechanical parameters (NOGA XP) and changes of myocardial ischemia in patients with refractory angina
Popis výsledku anglicky
Introduction: Cell therapy has the potential to improve symptoms and clinical outcomes in refractory angina (RFA). Further analyses are needed to evaluate factors influencing its therapeutic effectiveness. Aim: Assessment of electromechanical (EM) parameters of the left ventricle (LV) and investigation of correlation between EM parameters of the myocardium and response to CD133+ cell therapy. Material and methods: Thirty patients with RFA (16 active and 14 placebo individuals) enrolled in the REGENT-VSEL trial underwent EM evaluation of the LV with intracardiac mapping system. The following parameters were analyzed: unipolar voltage (UV), bipolar voltage (BV), local linear shortening (LLS). Myocardial ischemia was evaluated with single-photon emission computed tomography (SPECT). The median value of each EM parameter was used for intra-group comparisons. Results: Global EM parameters (UV, BV, LLS) of LV in active and placebo groups were 11.28 mV, 3.58 mV, 11.12%, respectively; 13.00 mV, 3.81 mV, 11.32%, respectively. EM characteristics analyzed at global and segmental levels did not predict response to CD133+ cell therapy in patients with RFA (Global UV, BV and LLS at rest R = -0.06; R = 0.2; R = -0.1 and at stress: R = 0.07, R = 0.09, R = -0.1, respectively; Segmental UV, BV, LLS at rest R = -0.2, R = 0.03, R = -0.4 and at stress R = 0.02, R = 0.2, R = -0.2, respectively). Multiple linear regression of the treated segments showed that only pre-injection SPECT levels were significantly correlated with post-injection SPECT, either at rest or stress (p < 0.05). Conclusions: Electromechanical characteristics of the left ventricle do not predict changes of myocardial perfusion by SPECT after cell therapy. Baseline SPECT results are only predictors of changes of myocardial ischemia observed at 4-month follow-up.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Postepy w Kardiologii Interwencyjnej
ISSN
1734-9338
e-ISSN
—
Svazek periodika
17
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
9
Strana od-do
281-289
Kód UT WoS článku
000714943600005