Autotitrating Bilevel Positive Airway Pressure in Large Vessel Steno-Occlusive Stroke Patients With Suspected Sleep Apnea: A Multicenter Randomized Controlled Study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F21%3A00075231" target="_blank" >RIV/00159816:_____/21:00075231 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/21:00121974
Výsledek na webu
<a href="https://www.frontiersin.org/articles/10.3389/fneur.2021.667494/full" target="_blank" >https://www.frontiersin.org/articles/10.3389/fneur.2021.667494/full</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3389/fneur.2021.667494" target="_blank" >10.3389/fneur.2021.667494</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Autotitrating Bilevel Positive Airway Pressure in Large Vessel Steno-Occlusive Stroke Patients With Suspected Sleep Apnea: A Multicenter Randomized Controlled Study
Popis výsledku v původním jazyce
Background: We hypothesized that autotitrating bilevel positive airway pressure (auto-BPAP) favorably affects short-term clinical outcomes in hyperacute ischemic stroke. Methods: In a multicenter, randomized, controlled trial patients with large vessel steno-occlusive stroke and clinically suspected sleep apnea were allocated to auto-BPAP or standard stroke care alone. Auto-BPAP was initiated within 24 h from stroke onset and performed over 48 h during diurnal and nocturnal sleep. Sleep apnea was assessed using cardiorespiratory polygraphy. Primary endpoint was early neurological improvement on National Institutes of Health Stroke Scale (NIHSS) score at 72 h. Safety and tolerability of BPAP, functional independence [modified Rankin Scale (mRS) 0-2], stroke recurrence, and mortality at 90 days were assessed. Results: Due to low recruitment, the trial was prematurely stopped after 24 patients had been randomized (auto-BPAP, n = 14; control, n = 10): median baseline NIHSS 13 (5.5-18), 88% large vessel occlusion, and 12% large vessel stenosis. Polygraphy confirmed sleep apnea in 64% of auto-BPAP and 88% of control patients (p = 0.34). Adherence to auto-BPAP was achieved by 9 of the 14 (64%) patients. Between auto-BPAP and control patients, no differences were observed in early neurological improvement (median NIHSS change: -2.0, IQR = 7 points vs. -0.5, IQR = 3 points), 90 days functional independence (21 vs. 30%, p = 0.67), stroke recurrence (0 vs. 20%, p = 0.16), and death (14 vs. 20%, p = 1.0). No safety concerns were identified. Conclusions: In this prematurely terminated trial, auto-BPAP was safe but did not show an effect on short-term clinical outcomes in selected ischemic stroke patients. Its tolerability, however, may be limited in hyperacute stroke care and needs to be improved before larger trials are conducted.
Název v anglickém jazyce
Autotitrating Bilevel Positive Airway Pressure in Large Vessel Steno-Occlusive Stroke Patients With Suspected Sleep Apnea: A Multicenter Randomized Controlled Study
Popis výsledku anglicky
Background: We hypothesized that autotitrating bilevel positive airway pressure (auto-BPAP) favorably affects short-term clinical outcomes in hyperacute ischemic stroke. Methods: In a multicenter, randomized, controlled trial patients with large vessel steno-occlusive stroke and clinically suspected sleep apnea were allocated to auto-BPAP or standard stroke care alone. Auto-BPAP was initiated within 24 h from stroke onset and performed over 48 h during diurnal and nocturnal sleep. Sleep apnea was assessed using cardiorespiratory polygraphy. Primary endpoint was early neurological improvement on National Institutes of Health Stroke Scale (NIHSS) score at 72 h. Safety and tolerability of BPAP, functional independence [modified Rankin Scale (mRS) 0-2], stroke recurrence, and mortality at 90 days were assessed. Results: Due to low recruitment, the trial was prematurely stopped after 24 patients had been randomized (auto-BPAP, n = 14; control, n = 10): median baseline NIHSS 13 (5.5-18), 88% large vessel occlusion, and 12% large vessel stenosis. Polygraphy confirmed sleep apnea in 64% of auto-BPAP and 88% of control patients (p = 0.34). Adherence to auto-BPAP was achieved by 9 of the 14 (64%) patients. Between auto-BPAP and control patients, no differences were observed in early neurological improvement (median NIHSS change: -2.0, IQR = 7 points vs. -0.5, IQR = 3 points), 90 days functional independence (21 vs. 30%, p = 0.67), stroke recurrence (0 vs. 20%, p = 0.16), and death (14 vs. 20%, p = 1.0). No safety concerns were identified. Conclusions: In this prematurely terminated trial, auto-BPAP was safe but did not show an effect on short-term clinical outcomes in selected ischemic stroke patients. Its tolerability, however, may be limited in hyperacute stroke care and needs to be improved before larger trials are conducted.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30210 - Clinical neurology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Frontiers in Neurology
ISSN
1664-2295
e-ISSN
—
Svazek periodika
12
Číslo periodika v rámci svazku
April
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
000644387900001
EID výsledku v databázi Scopus
—