Association of Stent-Retriever Characteristics in Establishing Successful Reperfusion During Mechanical Thrombectomy Results from the ESCAPE-NA1 Trial
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F22%3A00077740" target="_blank" >RIV/00159816:_____/22:00077740 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/22:00128452
Výsledek na webu
<a href="https://link.springer.com/article/10.1007/s00062-021-01123-0" target="_blank" >https://link.springer.com/article/10.1007/s00062-021-01123-0</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00062-021-01123-0" target="_blank" >10.1007/s00062-021-01123-0</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Association of Stent-Retriever Characteristics in Establishing Successful Reperfusion During Mechanical Thrombectomy Results from the ESCAPE-NA1 Trial
Popis výsledku v původním jazyce
Background Successful reperfusion determines the treatment effect of endovascular thrombectomy. We evaluated stent-retriever characteristics and their relation to reperfusion in the ESCAPE-NA1 trial. Methods Independent re-scoring of reperfusion grade for each attempt was conducted. The following characteristics were evaluated: stent-retriever length and diameter, thrombus position within stent-retriever, bypass effect, deployment in the superior or inferior MCA trunk, use of balloon guide catheter and distal access catheter. Primary outcome was successful reperfusion defined as expanded thrombolysis in cerebral infarction (eTICI) 2b-3 per attempt. The secondary outcome was successful reperfusion eTICI 2b-3 after the first attempt. Separate regression models for each stent-retriever characteristic and an exploratory multivariable modeling to test the impact of all characteristics on successful reperfusion were built. Results Of 1105 patients in the trial, 809 with the stent-retriever use (1241 attempts) were included in the primary analysis. The stent-retriever was used as the first-line approach in 751 attempts. A successful attempt was associated with thrombus position within the proximal or middle third of the stent (OR 2.06; 95% CI: 1.24-3.40 and OR 1.92; 95% CI: 1.16-3.15 compared to the distal third respectively) and with bypass effect (OR 1.7; 95% CI: 1.07-2.72). Thrombus position within the proximal or middle third (OR 2.80; 95% CI: 1.47-5.35 and OR 2.05; 95% CI: 1.09-3.84, respectively) was associated with first-pass eTICI 2b-3 reperfusion. In the exploratory analysis accounting for all characteristics, bypass effect was the only independent predictor of eTICI 2b-3 reperfusion (OR 1.95; 95% CI: 1.10-3.46). Conclusion The presence of bypass effect and thrombus positioning within the proximal and middle third of the stent-retriever were strongly associated with successful reperfusion.
Název v anglickém jazyce
Association of Stent-Retriever Characteristics in Establishing Successful Reperfusion During Mechanical Thrombectomy Results from the ESCAPE-NA1 Trial
Popis výsledku anglicky
Background Successful reperfusion determines the treatment effect of endovascular thrombectomy. We evaluated stent-retriever characteristics and their relation to reperfusion in the ESCAPE-NA1 trial. Methods Independent re-scoring of reperfusion grade for each attempt was conducted. The following characteristics were evaluated: stent-retriever length and diameter, thrombus position within stent-retriever, bypass effect, deployment in the superior or inferior MCA trunk, use of balloon guide catheter and distal access catheter. Primary outcome was successful reperfusion defined as expanded thrombolysis in cerebral infarction (eTICI) 2b-3 per attempt. The secondary outcome was successful reperfusion eTICI 2b-3 after the first attempt. Separate regression models for each stent-retriever characteristic and an exploratory multivariable modeling to test the impact of all characteristics on successful reperfusion were built. Results Of 1105 patients in the trial, 809 with the stent-retriever use (1241 attempts) were included in the primary analysis. The stent-retriever was used as the first-line approach in 751 attempts. A successful attempt was associated with thrombus position within the proximal or middle third of the stent (OR 2.06; 95% CI: 1.24-3.40 and OR 1.92; 95% CI: 1.16-3.15 compared to the distal third respectively) and with bypass effect (OR 1.7; 95% CI: 1.07-2.72). Thrombus position within the proximal or middle third (OR 2.80; 95% CI: 1.47-5.35 and OR 2.05; 95% CI: 1.09-3.84, respectively) was associated with first-pass eTICI 2b-3 reperfusion. In the exploratory analysis accounting for all characteristics, bypass effect was the only independent predictor of eTICI 2b-3 reperfusion (OR 1.95; 95% CI: 1.10-3.46). Conclusion The presence of bypass effect and thrombus positioning within the proximal and middle third of the stent-retriever were strongly associated with successful reperfusion.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30210 - Clinical neurology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Clinical Neuroradiology
ISSN
1869-1439
e-ISSN
1869-1447
Svazek periodika
32
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
799-807
Kód UT WoS článku
000739761200001
EID výsledku v databázi Scopus
—