Arthroscopic Transosseous Rotator Cuff Repair Using Bone Tunneling Device
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F25%3A00082422" target="_blank" >RIV/00159816:_____/25:00082422 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/25:00142048
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S2212628725001355?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S2212628725001355?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.eats.2025.103566" target="_blank" >10.1016/j.eats.2025.103566</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Arthroscopic Transosseous Rotator Cuff Repair Using Bone Tunneling Device
Popis výsledku v původním jazyce
Rotator cuff injuries are a common cause of shoulder pain, primarily affecting individuals older than 40 years, with the incidence increasing progressively with age. Advancements in surgical techniques have led to the development of arthroscopic techniques. This evolution has transitioned through various arthroscopic suture anchor rotator cuff repair configurations, including single-row, double-row, and transosseous-equivalent constructs. Although these innovations have replicated the biomechanics of the original transosseous technique conducted using an open approach, they often require multiple anchors, significantly increasing surgical costs. Additionally, anchor-related complications persist. To enhance the feasibility and affordability of implant-free transosseous repair, a reusable instrumentation system, was developed by Drillbone (Brno, Czechia). This innovative device facilitates robust and reproducible transosseous rotator cuff repairs while substantially reducing procedural costs. We present a surgical technique using bone tunneling device, showing its application in arthroscopic rotator cuff repair.
Název v anglickém jazyce
Arthroscopic Transosseous Rotator Cuff Repair Using Bone Tunneling Device
Popis výsledku anglicky
Rotator cuff injuries are a common cause of shoulder pain, primarily affecting individuals older than 40 years, with the incidence increasing progressively with age. Advancements in surgical techniques have led to the development of arthroscopic techniques. This evolution has transitioned through various arthroscopic suture anchor rotator cuff repair configurations, including single-row, double-row, and transosseous-equivalent constructs. Although these innovations have replicated the biomechanics of the original transosseous technique conducted using an open approach, they often require multiple anchors, significantly increasing surgical costs. Additionally, anchor-related complications persist. To enhance the feasibility and affordability of implant-free transosseous repair, a reusable instrumentation system, was developed by Drillbone (Brno, Czechia). This innovative device facilitates robust and reproducible transosseous rotator cuff repairs while substantially reducing procedural costs. We present a surgical technique using bone tunneling device, showing its application in arthroscopic rotator cuff repair.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30211 - Orthopaedics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Arthroscopy Techniques
ISSN
2212-6287
e-ISSN
2212-6287
Svazek periodika
14
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
nestránkováno
Kód UT WoS článku
001548196500023
EID výsledku v databázi Scopus
—