Monte Carlo Study of Reference Photon Fields in the Irradiation Halls of the Czech Metrology Institute
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F07%3A%230000161" target="_blank" >RIV/00177016:_____/07:#0000161 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Monte Carlo Study of Reference Photon Fields in the Irradiation Halls of the Czech Metrology Institute
Popis výsledku v původním jazyce
The MCNPX code was used to obtain characteristics of collimated photon beams from a metrological 60Co source and a former radiotherapy 60Co irradiator ?Chisobalt 2 B75? exploited for calibration and verification of dosimeters in the Czech Metrology Institute ? Inspectorate for Ionizing Radiation (CMI-IIR; Czech metrology body). First, for each source, a longitudinal profile of air-kerma rate on the beam axis and a transversal profile of air-kerma rate at a distance of 1 m from the front of the collimator were simulated and the results were compared to the experimental data obtained with ionization chambers. Relative comparison shows good agreement. Second, the number of scattered photons in the fluence spectra along and across the beam axes and their contribution to air-kerma was specified. Third, the individual contributions of collimator, air, floor, walls, mobile platform, and other parts of the irradiation halls to the overall air-kerma on the beam axes were calculated.
Název v anglickém jazyce
Monte Carlo Study of Reference Photon Fields in the Irradiation Halls of the Czech Metrology Institute
Popis výsledku anglicky
The MCNPX code was used to obtain characteristics of collimated photon beams from a metrological 60Co source and a former radiotherapy 60Co irradiator ?Chisobalt 2 B75? exploited for calibration and verification of dosimeters in the Czech Metrology Institute ? Inspectorate for Ionizing Radiation (CMI-IIR; Czech metrology body). First, for each source, a longitudinal profile of air-kerma rate on the beam axis and a transversal profile of air-kerma rate at a distance of 1 m from the front of the collimator were simulated and the results were compared to the experimental data obtained with ionization chambers. Relative comparison shows good agreement. Second, the number of scattered photons in the fluence spectra along and across the beam axes and their contribution to air-kerma was specified. Third, the individual contributions of collimator, air, floor, walls, mobile platform, and other parts of the irradiation halls to the overall air-kerma on the beam axes were calculated.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
R - Projekt Ramcoveho programu EK
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Svazek periodika
580
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—