A Joint Research Project to improve the accuracy in dosimetry of brachytherapy treatments in the framework of the European Metrology Research Programme
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F09%3A%230000169" target="_blank" >RIV/00177016:_____/09:#0000169 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Joint Research Project to improve the accuracy in dosimetry of brachytherapy treatments in the framework of the European Metrology Research Programme
Popis výsledku v původním jazyce
This paper outlines the joint research project ?Increasing cancer treatment efficacy using 3D brachytherapy? co-funded in the FP7, according to the iMERA-Plus Grant Agreement No. 217257 between the EC and EURAMET e. V. (European Association of National Metrology Institutes). The project brings together the capabilities of ten major European National Metrology Institutes in the ionizing radiation field and it is focused on the targeted programme ?Health?. It aims at establishing across Europe a more accurate metrological basis in brachytherapy by developing methods for the direct measurement of the quantity absorbed dose to water in brachytherapy dosimetry with an uncertainty on the dose delivered to the target volume less than 5% (k=1) at clinical level.
Název v anglickém jazyce
A Joint Research Project to improve the accuracy in dosimetry of brachytherapy treatments in the framework of the European Metrology Research Programme
Popis výsledku anglicky
This paper outlines the joint research project ?Increasing cancer treatment efficacy using 3D brachytherapy? co-funded in the FP7, according to the iMERA-Plus Grant Agreement No. 217257 between the EC and EURAMET e. V. (European Association of National Metrology Institutes). The project brings together the capabilities of ten major European National Metrology Institutes in the ionizing radiation field and it is focused on the targeted programme ?Health?. It aims at establishing across Europe a more accurate metrological basis in brachytherapy by developing methods for the direct measurement of the quantity absorbed dose to water in brachytherapy dosimetry with an uncertainty on the dose delivered to the target volume less than 5% (k=1) at clinical level.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
R - Projekt Ramcoveho programu EK
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
World Congress on Medical Physics and Biomedical Engineering
ISBN
9783642034725
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Springer
Místo vydání
—
Místo konání akce
Munich, Germany
Datum konání akce
1. 1. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—