Advanced Procedures for Calibration of Instrument Transformer Burdens
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F11%3A%230000425" target="_blank" >RIV/00177016:_____/11:#0000425 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.isie2011.pl/" target="_blank" >http://www.isie2011.pl/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Advanced Procedures for Calibration of Instrument Transformer Burdens
Popis výsledku v původním jazyce
Measurement of electrical power or energy in the area of electroenergetic, power systems and electric drivers is closely linked with use of instrument current or voltage transformers (ICT, IVT). Accuracy of these appliances substantially affects the resulting accuracy of the measurement. An important parameter which affects ICT or IVT accuracy is their burden. Therefore the calibration of instrument transformers (IT) must be performed at a desired value of the burden. It usually varies in the range (1 up to 75) VA. ICT burdens less than 5 VA are usually real or they have the inductive power factor 0.8 for greater values. IVT burdens have usually inductive power factor 0.8. A precise adjusting of the burden is important to achieve required IT calibration accuracy. Burden calibration is a necessary part of the calibration process. Procedures for burden calibration used at CMI are described in the paper.
Název v anglickém jazyce
Advanced Procedures for Calibration of Instrument Transformer Burdens
Popis výsledku anglicky
Measurement of electrical power or energy in the area of electroenergetic, power systems and electric drivers is closely linked with use of instrument current or voltage transformers (ICT, IVT). Accuracy of these appliances substantially affects the resulting accuracy of the measurement. An important parameter which affects ICT or IVT accuracy is their burden. Therefore the calibration of instrument transformers (IT) must be performed at a desired value of the burden. It usually varies in the range (1 up to 75) VA. ICT burdens less than 5 VA are usually real or they have the inductive power factor 0.8 for greater values. IVT burdens have usually inductive power factor 0.8. A precise adjusting of the burden is important to achieve required IT calibration accuracy. Burden calibration is a necessary part of the calibration process. Procedures for burden calibration used at CMI are described in the paper.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ISIE 2011 - International Symposium on Industrial Electronics
ISBN
978-1-4244-9311-1
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
983-988
Název nakladatele
IEEE
Místo vydání
Varšava
Místo konání akce
Gdaňsk
Datum konání akce
1. 1. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—