Supplementary comparison CCRI(I)-S2 of standards for absorbed dose to water in 60Co gamma radiation at radiation processing dose levels
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F11%3A%230000869" target="_blank" >RIV/00177016:_____/11:#0000869 - isvavai.cz</a>
Výsledek na webu
<a href="http://iopscience.iop.org/0026-1394/48/1A/06009/" target="_blank" >http://iopscience.iop.org/0026-1394/48/1A/06009/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/0026-1394/48/1A/06009" target="_blank" >10.1088/0026-1394/48/1A/06009</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Supplementary comparison CCRI(I)-S2 of standards for absorbed dose to water in 60Co gamma radiation at radiation processing dose levels
Popis výsledku v původním jazyce
Eight national standards for absorbed dose to water in 60Co gamma radiation at the dose levels used in radiation processing have been compared over the range from 1 kGy to 30 kGy using the alanine dosimeters of the NIST and the NPL as the transfer dosimeters. The comparison was organized by the Bureau International des Poids et Mesures, who also participated at the lowest dose level using their radiotherapy-level standard for the same quantity. The national standards are in general agreement within thestandard uncertainties, which are in the range from 1 to 2 parts in 102. Evidence of a dose rate effect is presented and discussed briefly.
Název v anglickém jazyce
Supplementary comparison CCRI(I)-S2 of standards for absorbed dose to water in 60Co gamma radiation at radiation processing dose levels
Popis výsledku anglicky
Eight national standards for absorbed dose to water in 60Co gamma radiation at the dose levels used in radiation processing have been compared over the range from 1 kGy to 30 kGy using the alanine dosimeters of the NIST and the NPL as the transfer dosimeters. The comparison was organized by the Bureau International des Poids et Mesures, who also participated at the lowest dose level using their radiotherapy-level standard for the same quantity. The national standards are in general agreement within thestandard uncertainties, which are in the range from 1 to 2 parts in 102. Evidence of a dose rate effect is presented and discussed briefly.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Metrologia
ISSN
0026-1394
e-ISSN
—
Svazek periodika
48
Číslo periodika v rámci svazku
—
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
18
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—