An influence of different medium in generator at elevated pressure
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F13%3A%230000982" target="_blank" >RIV/00177016:_____/13:#0000982 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
An influence of different medium in generator at elevated pressure
Popis výsledku v původním jazyce
Thermal properties department of the Czech Metrology Institute developed unique device, suitable for the humidity measurement in the range (5 to 95) % RH. This device ? primary humidity generator, was designed and constructed by CMI and allows differentmeasurement setups. Development of the presented facility was inspired by requirements of the natural gas transport companies. Nowadays, calibration and traceability of the dew-point humidity sensors is performed in presence of the air. To obtain resultsas good as possible is necessary to perform the calibration in conditions approaching the real state ? calibration in high pressure with the flowing medium with the similar composition as the really used gas. Presented device can be described as 1P1T generator. This mean, that final humidity is dependent on the one pressure and one temperature. Generator allows to measure dew point under different pressures up to 15 MPa in presence of the various gaseous media (O2, CH4, CO2). Saturator,
Název v anglickém jazyce
An influence of different medium in generator at elevated pressure
Popis výsledku anglicky
Thermal properties department of the Czech Metrology Institute developed unique device, suitable for the humidity measurement in the range (5 to 95) % RH. This device ? primary humidity generator, was designed and constructed by CMI and allows differentmeasurement setups. Development of the presented facility was inspired by requirements of the natural gas transport companies. Nowadays, calibration and traceability of the dew-point humidity sensors is performed in presence of the air. To obtain resultsas good as possible is necessary to perform the calibration in conditions approaching the real state ? calibration in high pressure with the flowing medium with the similar composition as the really used gas. Presented device can be described as 1P1T generator. This mean, that final humidity is dependent on the one pressure and one temperature. Generator allows to measure dew point under different pressures up to 15 MPa in presence of the various gaseous media (O2, CH4, CO2). Saturator,
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BJ - Termodynamika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Symposium on Temperature and Thermal Measurements in Industry and Science
ISBN
978-972-8574-15-4
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
361
Název nakladatele
—
Místo vydání
—
Místo konání akce
Funchal, Madeira
Datum konání akce
14. 10. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—