Metrological Issues in Molecular Radiotherapy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F14%3A%230000871" target="_blank" >RIV/00177016:_____/14:#0000871 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1051/epjconf/20147700022" target="_blank" >http://dx.doi.org/10.1051/epjconf/20147700022</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/20147700022" target="_blank" >10.1051/epjconf/20147700022</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Metrological Issues in Molecular Radiotherapy
Popis výsledku v původním jazyce
The therapeutic effect from molecular radiation therapy (MRT), on both tumour and normal tissue, is determined by the radiation absorbed dose. Recent research indicates that as a consequence of biological variation across patients the absorbed dose can vary, for the same administered activity, by as much as two orders of magnitude. The international collaborative EURAMET-EMRP project ?Metrology for molecular radiotherapy (MetroMRT)? is addressing this problem. The overall aim of the project is to develop methods of calibrating and verifying clinical dosimetry in MRT. In the present paper an overview of the metrological issues in molecular radiotherapy is provided.
Název v anglickém jazyce
Metrological Issues in Molecular Radiotherapy
Popis výsledku anglicky
The therapeutic effect from molecular radiation therapy (MRT), on both tumour and normal tissue, is determined by the radiation absorbed dose. Recent research indicates that as a consequence of biological variation across patients the absorbed dose can vary, for the same administered activity, by as much as two orders of magnitude. The international collaborative EURAMET-EMRP project ?Metrology for molecular radiotherapy (MetroMRT)? is addressing this problem. The overall aim of the project is to develop methods of calibrating and verifying clinical dosimetry in MRT. In the present paper an overview of the metrological issues in molecular radiotherapy is provided.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/7AX13003" target="_blank" >7AX13003: Metrology for molecular radiotherapy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
EPJ Web of Conferences
ISSN
2100-014X
e-ISSN
—
Svazek periodika
77
Číslo periodika v rámci svazku
19.8.2014
Stát vydavatele periodika
FR - Francouzská republika
Počet stran výsledku
7
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—