Bilateral Comparison Between CMI and CEM in Radiance Temperature Scale Realization from TeX to TeX
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F14%3A%230001021" target="_blank" >RIV/00177016:_____/14:#0001021 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Bilateral Comparison Between CMI and CEM in Radiance Temperature Scale Realization from TeX to TeX
Popis výsledku v původním jazyce
A bilateral comparison between the Centro Espa?ol de Metrología (CEM) and the Český Metrologický Institut (CMI) of radiance temperature scale realizations in the range from 232°C to 1085°C was carried out during 2012 to support the calibration measurements capabilities of CMI in radiation thermometry. The CEM capabilities were demonstrated previously in a recent comparison of European laboratories over the range from 156°C to 1000°C . A CMI KE-LP5 radiation thermometer, working at 1568 nm, was used as atraveling standard. CEM measurements were done at the fixed-points (FPs) of Zn, Ag, and Cu and, for the rest of the temperatures, variable temperature blackbodies (VTBBs) were used. CMI measurements were done at the FPs of Sn, Al, and Cu, and the rest of the temperatures were measured with VTBBs. The size-of-source effect was measured at CEM to decide whether or not the measurements from both laboratories should be corrected by this effect (when the diameter of the sources was different
Název v anglickém jazyce
Bilateral Comparison Between CMI and CEM in Radiance Temperature Scale Realization from TeX to TeX
Popis výsledku anglicky
A bilateral comparison between the Centro Espa?ol de Metrología (CEM) and the Český Metrologický Institut (CMI) of radiance temperature scale realizations in the range from 232°C to 1085°C was carried out during 2012 to support the calibration measurements capabilities of CMI in radiation thermometry. The CEM capabilities were demonstrated previously in a recent comparison of European laboratories over the range from 156°C to 1000°C . A CMI KE-LP5 radiation thermometer, working at 1568 nm, was used as atraveling standard. CEM measurements were done at the fixed-points (FPs) of Zn, Ag, and Cu and, for the rest of the temperatures, variable temperature blackbodies (VTBBs) were used. CMI measurements were done at the FPs of Sn, Al, and Cu, and the rest of the temperatures were measured with VTBBs. The size-of-source effect was measured at CEM to decide whether or not the measurements from both laboratories should be corrected by this effect (when the diameter of the sources was different
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BJ - Termodynamika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/7AX12096" target="_blank" >7AX12096: Metrologie pro vysoké teploty v průmyslových aplikacích (>1000 °C)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Jurnal of Thermophysics
ISSN
1572-9567
e-ISSN
—
Svazek periodika
35
Číslo periodika v rámci svazku
3-4
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
9
Strana od-do
475-484
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—