Internal and external influences in the realization of ITS-90
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F15%3A%230001167" target="_blank" >RIV/00177016:_____/15:#0001167 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Internal and external influences in the realization of ITS-90
Popis výsledku v původním jazyce
In the realization of international temperature scale (ITS-90) is important to keep the requirements of Supplementary documents realized by BIPM. In addition of that, every national institute has their own requirements for proper realization of ITS-90. The aim of this work is to provide inputs for better understanding of the processes inside and outside of the metal fixed point?s cells. There are four main contributors for the overall calibration uncertainty of standard platinum resistance thermometer (SPRT) according to the ITS-90. - Fixed points - SPRT - Instrumentation -External influences This article will deal with influences of SPRT and ambient environment to the results. In first part, the subranges inconsistencies will be investigated on several types of SPRT calibrated in the laboratory of CMI. Interpolation uncertainty will be compared with the results of least squares method for these SPRT. Second part will deal with influences of furnaces used for the realisation of the fix
Název v anglickém jazyce
Internal and external influences in the realization of ITS-90
Popis výsledku anglicky
In the realization of international temperature scale (ITS-90) is important to keep the requirements of Supplementary documents realized by BIPM. In addition of that, every national institute has their own requirements for proper realization of ITS-90. The aim of this work is to provide inputs for better understanding of the processes inside and outside of the metal fixed point?s cells. There are four main contributors for the overall calibration uncertainty of standard platinum resistance thermometer (SPRT) according to the ITS-90. - Fixed points - SPRT - Instrumentation -External influences This article will deal with influences of SPRT and ambient environment to the results. In first part, the subranges inconsistencies will be investigated on several types of SPRT calibrated in the laboratory of CMI. Interpolation uncertainty will be compared with the results of least squares method for these SPRT. Second part will deal with influences of furnaces used for the realisation of the fix
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
O - Projekt operacniho programu
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
—
Místo vydání
—
Název nakladatele resp. objednatele
—
Verze
—
Identifikační číslo nosiče
—