Different blackbody geometry and distance of measurement influence on the calibration results of hand infrared thermometers.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F15%3A%230001168" target="_blank" >RIV/00177016:_____/15:#0001168 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Different blackbody geometry and distance of measurement influence on the calibration results of hand infrared thermometers.
Popis výsledku v původním jazyce
Portable hand infrared thermometers are very popular at end users level for common measurements. A lot of types with big variety of their properties are available on the market. As a key condition for proper temperature measurement looks to perform measurement from right distance with an object with sufficient dimensions. Manufacturers provide information how the measurement spot should changes with a distance. Otherwise, no information about the change of temperature in dependency on the distance is provided. Aim of presented work was investigate how the result of calibration may vary when different types of the blackbodies are used and when the measurement distance is changing. Three blackbodies were used for measurements: heat pipe blackbody, blackbody with spherical cavity and common flat plate blackbody. Presented case study was performed at 3 thermometers at least, with different optic specification, working in wavelength range (8 to 14) ?m. Measurements were performed at differe
Název v anglickém jazyce
Different blackbody geometry and distance of measurement influence on the calibration results of hand infrared thermometers.
Popis výsledku anglicky
Portable hand infrared thermometers are very popular at end users level for common measurements. A lot of types with big variety of their properties are available on the market. As a key condition for proper temperature measurement looks to perform measurement from right distance with an object with sufficient dimensions. Manufacturers provide information how the measurement spot should changes with a distance. Otherwise, no information about the change of temperature in dependency on the distance is provided. Aim of presented work was investigate how the result of calibration may vary when different types of the blackbodies are used and when the measurement distance is changing. Three blackbodies were used for measurements: heat pipe blackbody, blackbody with spherical cavity and common flat plate blackbody. Presented case study was performed at 3 thermometers at least, with different optic specification, working in wavelength range (8 to 14) ?m. Measurements were performed at differe
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů