A single-ion trap with minimized ion?environment interactions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F16%3A%230001222" target="_blank" >RIV/00177016:_____/16:#0001222 - isvavai.cz</a>
Výsledek na webu
<a href="http://link.springer.com/10.1007/s00340-016-6327-x" target="_blank" >http://link.springer.com/10.1007/s00340-016-6327-x</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00340-016-6327-x" target="_blank" >10.1007/s00340-016-6327-x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A single-ion trap with minimized ion?environment interactions
Popis výsledku v původním jazyce
We present a new single-ion endcap trap for high-precision spectroscopy that has been designed to minimize ion?environment interactions. We describe the design in detail and then characterize the working trap using a single trapped 171Yb+ ion. Excess micromotion has been eliminated to the resolution of the detection method, and the trap exhibits an anomalous phonon heating rate of dn/dt = 24+30 -24 s-1. The thermal properties of the trap structure have also been measured with an effective temperature rise at the ion?s position of T(ion) = 0.14 ? 0.14K. The small perturbations to the ion caused by this trap make it suitable to be used for an optical frequency standard with fractional uncertainties below the 10-18 level.
Název v anglickém jazyce
A single-ion trap with minimized ion?environment interactions
Popis výsledku anglicky
We present a new single-ion endcap trap for high-precision spectroscopy that has been designed to minimize ion?environment interactions. We describe the design in detail and then characterize the working trap using a single trapped 171Yb+ ion. Excess micromotion has been eliminated to the resolution of the detection method, and the trap exhibits an anomalous phonon heating rate of dn/dt = 24+30 -24 s-1. The thermal properties of the trap structure have also been measured with an effective temperature rise at the ion?s position of T(ion) = 0.14 ? 0.14K. The small perturbations to the ion caused by this trap make it suitable to be used for an optical frequency standard with fractional uncertainties below the 10-18 level.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/7AX13011" target="_blank" >7AX13011: High-accuracy optical clocks with trapped ions</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Physics B
ISSN
0946-2171
e-ISSN
—
Svazek periodika
122
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
1-8
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—