CCEM key comparison CCEM.RF-K23.F
Popis výsledku v původním jazyce
The CCEM international antenna gain comparison CCEM.RF- K23.F was initiated by the Working Group on Radio Frequency quantities (GT_RF) on the Consultative Committee for Electricity and Magnetism. This key comparison report presents results of measurements of on-axis gain of two Ku-band pyramidal horns at 12.4, 15, and 18 GHz. Participants making corrections for mismatch were asked to provide a table of the real and imaginary parts of the reflection coefficients of the antennas. Optionally, participants could measure the swept frequency gain from 12.4 to 18 GHz. Twelve national laboratories participated. The National Institute of Standards and Technology from the United States was the pilot lab. The purpose of the comparison was to evaluate the consistency between the participating laboratories in the measurement of the boresight gain of horn antennas in the WR-62 band.
Název v anglickém jazyce
CCEM key comparison CCEM.RF-K23.F
Popis výsledku anglicky
The CCEM international antenna gain comparison CCEM.RF- K23.F was initiated by the Working Group on Radio Frequency quantities (GT_RF) on the Consultative Committee for Electricity and Magnetism. This key comparison report presents results of measurements of on-axis gain of two Ku-band pyramidal horns at 12.4, 15, and 18 GHz. Participants making corrections for mismatch were asked to provide a table of the real and imaginary parts of the reflection coefficients of the antennas. Optionally, participants could measure the swept frequency gain from 12.4 to 18 GHz. Twelve national laboratories participated. The National Institute of Standards and Technology from the United States was the pilot lab. The purpose of the comparison was to evaluate the consistency between the participating laboratories in the measurement of the boresight gain of horn antennas in the WR-62 band.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Metrologia
ISSN
0026-1394
e-ISSN
1681-7575
Svazek periodika
53
Číslo periodika v rámci svazku
1A
Stát vydavatele periodika
FR - Francouzská republika
Počet stran výsledku
115
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85013936977