Waveform Characterization of Calibration-Pulse Generators for EMI Measuring Receivers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F19%3AN0000028" target="_blank" >RIV/00177016:_____/19:N0000028 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/8872000" target="_blank" >https://ieeexplore.ieee.org/document/8872000</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EMCEurope.2019.8872000" target="_blank" >10.1109/EMCEurope.2019.8872000</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Waveform Characterization of Calibration-Pulse Generators for EMI Measuring Receivers
Popis výsledku v původním jazyce
This paper presents the waveform characterization of calibration pulse generators intended to evaluate the response to pulses of the weighting detectors in CISPR 16-1-1 measuring receivers. First, the standard requirements of the reference pulses are described, and the pulse generators calibration methods based on waveform measurements are briefly discussed. Then, high-resolution time domain measurements are used for characterizing the waveforms of a commercial calibration-pulse generator in terms of rise/fall time, pulse width, mean voltage of the upper state, repetition frequency, and area. Moreover, the results above are used for estimating the spectral density of the impulses, their corresponding quasi-peak level, the pulses bandwidth, and the breakpoint frequencies. Finally, the measurement uncertainty is estimated for CISPR bands A, B, and C/D. Results are in good agreement with other calibrations performed during an intercomparison exercise and the uncertainty satisfy the target ±0.5 dB and 1% given in standards for the impulse area and pulse repetition frequency respectively.
Název v anglickém jazyce
Waveform Characterization of Calibration-Pulse Generators for EMI Measuring Receivers
Popis výsledku anglicky
This paper presents the waveform characterization of calibration pulse generators intended to evaluate the response to pulses of the weighting detectors in CISPR 16-1-1 measuring receivers. First, the standard requirements of the reference pulses are described, and the pulse generators calibration methods based on waveform measurements are briefly discussed. Then, high-resolution time domain measurements are used for characterizing the waveforms of a commercial calibration-pulse generator in terms of rise/fall time, pulse width, mean voltage of the upper state, repetition frequency, and area. Moreover, the results above are used for estimating the spectral density of the impulses, their corresponding quasi-peak level, the pulses bandwidth, and the breakpoint frequencies. Finally, the measurement uncertainty is estimated for CISPR bands A, B, and C/D. Results are in good agreement with other calibrations performed during an intercomparison exercise and the uncertainty satisfy the target ±0.5 dB and 1% given in standards for the impulse area and pulse repetition frequency respectively.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/8B16005" target="_blank" >8B16005: Development of RF and microwave metrology capability</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2019 International Symposium on Electromagnetic Compatibility - EMC EUROPE
ISBN
978-1-7281-0594-9
ISSN
2325-0364
e-ISSN
—
Počet stran výsledku
5
Strana od-do
614-618
Název nakladatele
IEEE
Místo vydání
Barcelona, Španělsko
Místo konání akce
Barcelona, Španělsko
Datum konání akce
2. 9. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce