Measurement of high power
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F19%3AN0000087" target="_blank" >RIV/00177016:_____/19:N0000087 - isvavai.cz</a>
Výsledek na webu
<a href="http://rfmw.cmi.cz/index.php/download/54-bpguides.html" target="_blank" >http://rfmw.cmi.cz/index.php/download/54-bpguides.html</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of high power
Popis výsledku v původním jazyce
RF&MW Power traceability is established at mW levels using microcalorimeters as reference devices. They are used mainly by NMIs to calibrate thermistors, thermal or diode power sensors which are then used by calibration laboratories for traceable measurements and calibrations of RF&MW power. These sensors are upward limited to power levels which can be directly measured, which is typically about up to 100mW or 1W (+20 dBm to +30dBm). To be able to measure higher powers up to kW range in a traceable manner, additional reference attenuators and/or couplers have to be used to lower the level suitably for measurements using traceable mW range power sensors. Those reference attenuators and couplers have to be traceably calibrated and their influence considered when measuring power and calculating measurement uncertainty. This guide will show on how to use mW range power sensors and reference attenuators or couplers to measure high power in a traceable manner and show uncertainty calculation for different cases. The guide will show how calculations and corrections can be considered if complex values are available for reference equipment together with the estimation of uncertainty and also for cases when only magnitudes for reference equipment is calibrated or known.
Název v anglickém jazyce
Measurement of high power
Popis výsledku anglicky
RF&MW Power traceability is established at mW levels using microcalorimeters as reference devices. They are used mainly by NMIs to calibrate thermistors, thermal or diode power sensors which are then used by calibration laboratories for traceable measurements and calibrations of RF&MW power. These sensors are upward limited to power levels which can be directly measured, which is typically about up to 100mW or 1W (+20 dBm to +30dBm). To be able to measure higher powers up to kW range in a traceable manner, additional reference attenuators and/or couplers have to be used to lower the level suitably for measurements using traceable mW range power sensors. Those reference attenuators and couplers have to be traceably calibrated and their influence considered when measuring power and calculating measurement uncertainty. This guide will show on how to use mW range power sensors and reference attenuators or couplers to measure high power in a traceable manner and show uncertainty calculation for different cases. The guide will show how calculations and corrections can be considered if complex values are available for reference equipment together with the estimation of uncertainty and also for cases when only magnitudes for reference equipment is calibrated or known.
Klasifikace
Druh
V<sub>souhrn</sub> - Souhrnná výzkumná zpráva
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/8B16005" target="_blank" >8B16005: Development of RF and microwave metrology capability</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Počet stran výsledku
27
Místo vydání
Ljubljana, Slovenia
Název nakladatele resp. objednatele
EURAMET
Verze
—