The design and development of a tuneable and portable radiation source for in situ spectrometer characterisation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F21%3AN0000078" target="_blank" >RIV/00177016:_____/21:N0000078 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00177016:_____/20:N0000033
Výsledek na webu
<a href="https://amt.copernicus.org/articles/14/3573/2021/amt-14-3573-2021.pdf" target="_blank" >https://amt.copernicus.org/articles/14/3573/2021/amt-14-3573-2021.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5194/amt-14-3573-2021" target="_blank" >10.5194/amt-14-3573-2021</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The design and development of a tuneable and portable radiation source for in situ spectrometer characterisation
Popis výsledku v původním jazyce
We designed and developed a tuneable and portable radiation source (TuPS) to provide a reference wavelength scale, with a bandwidth of emitted radiation of 0.13 nm and uncertainty in wavelength of 0.02 nm. TuPS was successfully used for the in-field characterization of 14 Dobson spectrophotometers in campaigns in Europe. The line spread functions of Dobsons measured by TuPS in conjunction with the cross-sections from IUP improves the consistency between the Dobson and Brewer from 3 % to 1 %
Název v anglickém jazyce
The design and development of a tuneable and portable radiation source for in situ spectrometer characterisation
Popis výsledku anglicky
We designed and developed a tuneable and portable radiation source (TuPS) to provide a reference wavelength scale, with a bandwidth of emitted radiation of 0.13 nm and uncertainty in wavelength of 0.02 nm. TuPS was successfully used for the in-field characterization of 14 Dobson spectrophotometers in campaigns in Europe. The line spread functions of Dobsons measured by TuPS in conjunction with the cross-sections from IUP improves the consistency between the Dobson and Brewer from 3 % to 1 %
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
<a href="/cs/project/7AX15016" target="_blank" >7AX15016: Traceability for atmospheric total column ozone</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Atmospheric Measurement Techniques
ISSN
1867-1381
e-ISSN
1867-8548
Svazek periodika
14
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
10
Strana od-do
3573-3582
Kód UT WoS článku
000654333000001
EID výsledku v databázi Scopus
—