FLOMEKO 2022 - Insertion Depth Effect for Vane Anemometers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F22%3AN0000118" target="_blank" >RIV/00177016:_____/22:N0000118 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
FLOMEKO 2022 - Insertion Depth Effect for Vane Anemometers
Popis výsledku v původním jazyce
FLOMEKO 2022 - conference paper In this paper we show that velocity indication of a vane anemometer in a wind tunnel can significantly and non-trivially depend on length of the part of the anemometer’s mounting rod which is exposed to flow – the so-called insertion depth. The insertion depth dependencies for four vane anemometers with various dimensions are presented. For a small size vane anemometer with a propeller diameter of 22 mm, for example, a change of the insertion depth by 10 cm can cause a reading variation by up to 5 % - a value which is an order of magnitude larger than a typical expanded uncertainty of calibration in wind speed laboratories of national metrology institutes. Therefore, this effect has important consequences for selection of transfer standards for interlaboratory comparisons, since each participant can have a different insertion depth value, and also for the calibration practice where possible differences between the insertion depth of the user and the calibration laboratory should be taken into account.
Název v anglickém jazyce
FLOMEKO 2022 - Insertion Depth Effect for Vane Anemometers
Popis výsledku anglicky
FLOMEKO 2022 - conference paper In this paper we show that velocity indication of a vane anemometer in a wind tunnel can significantly and non-trivially depend on length of the part of the anemometer’s mounting rod which is exposed to flow – the so-called insertion depth. The insertion depth dependencies for four vane anemometers with various dimensions are presented. For a small size vane anemometer with a propeller diameter of 22 mm, for example, a change of the insertion depth by 10 cm can cause a reading variation by up to 5 % - a value which is an order of magnitude larger than a typical expanded uncertainty of calibration in wind speed laboratories of national metrology institutes. Therefore, this effect has important consequences for selection of transfer standards for interlaboratory comparisons, since each participant can have a different insertion depth value, and also for the calibration practice where possible differences between the insertion depth of the user and the calibration laboratory should be taken into account.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20302 - Applied mechanics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů