A Digital Bridge Evaluation up to 100 kHz for Precision Impedance Measurements
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F23%3AN0000028" target="_blank" >RIV/00177016:_____/23:N0000028 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/10122488/authors#authors" target="_blank" >https://ieeexplore.ieee.org/document/10122488/authors#authors</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/TIM.2023.3273649" target="_blank" >10.1109/TIM.2023.3273649</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Digital Bridge Evaluation up to 100 kHz for Precision Impedance Measurements
Popis výsledku v původním jazyce
A digital coaxial bridge was evaluated for its frequency extension up to 100 kHz using impedance standards with known reference values. The bridge can be configured in different modes of what are known as digitally assisted (DA) or fully digital (FD) modes, and both were studied. The measurement results showed that the FD bridge cannot reach an accuracy below 100×10−6 at 100 kHz, even for 1:1 comparison, unlike the DA bridge. Thus, an additional voltage injection method was attempted to achieve better accuracy for the FD bridge. As a result, 10:1 capacitance ratio measurements showed a good agreement with the reference values at the level of 10−5 for both DA and FD bridges at the highest frequency of 100 kHz.
Název v anglickém jazyce
A Digital Bridge Evaluation up to 100 kHz for Precision Impedance Measurements
Popis výsledku anglicky
A digital coaxial bridge was evaluated for its frequency extension up to 100 kHz using impedance standards with known reference values. The bridge can be configured in different modes of what are known as digitally assisted (DA) or fully digital (FD) modes, and both were studied. The measurement results showed that the FD bridge cannot reach an accuracy below 100×10−6 at 100 kHz, even for 1:1 comparison, unlike the DA bridge. Thus, an additional voltage injection method was attempted to achieve better accuracy for the FD bridge. As a result, 10:1 capacitance ratio measurements showed a good agreement with the reference values at the level of 10−5 for both DA and FD bridges at the highest frequency of 100 kHz.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/8B19009" target="_blank" >8B19009: Graphene impedance quantum standard</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IEEE Transactions on Instrumentation and Measurement
ISSN
0018-9456
e-ISSN
1557-9662
Svazek periodika
72
Číslo periodika v rámci svazku
09 May 2023
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
000996515600011
EID výsledku v databázi Scopus
2-s2.0-85159844092