On the use of solid 133Ba sources as surrogate for liquid 131I in SPECT/CT calibration: a European multi‑centre evaluation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F23%3AN0000086" target="_blank" >RIV/00177016:_____/23:N0000086 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1186/s40658-023-00582-3" target="_blank" >https://doi.org/10.1186/s40658-023-00582-3</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s40658-023-00582-3" target="_blank" >10.1186/s40658-023-00582-3</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
On the use of solid 133Ba sources as surrogate for liquid 131I in SPECT/CT calibration: a European multi‑centre evaluation
Popis výsledku v původním jazyce
Calibration, and quality control procedures for nuclear medicine imaging systems are typically performed using hollow containers filled with radionuclide solutions. This leads to multiple sources of uncertainty, many of which can be overcome by using traceable, sealed, long-lived surrogate sources containing a radionuclide of comparable energies and emission probabilities. This study presents the results of a quantitative SPECT/CT imaging comparison exercise performed within the MRTDosimetry consortium to assess the feasibility of using 133Ba as a surrogate for 131I imaging.
Název v anglickém jazyce
On the use of solid 133Ba sources as surrogate for liquid 131I in SPECT/CT calibration: a European multi‑centre evaluation
Popis výsledku anglicky
Calibration, and quality control procedures for nuclear medicine imaging systems are typically performed using hollow containers filled with radionuclide solutions. This leads to multiple sources of uncertainty, many of which can be overcome by using traceable, sealed, long-lived surrogate sources containing a radionuclide of comparable energies and emission probabilities. This study presents the results of a quantitative SPECT/CT imaging comparison exercise performed within the MRTDosimetry consortium to assess the feasibility of using 133Ba as a surrogate for 131I imaging.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
<a href="/cs/project/8B16002" target="_blank" >8B16002: Metrology for clinical implementation of dosimetry in molecular radiotherapy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
EJNMMI Physics
ISSN
2197-7364
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
73
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
16
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—