Characterization of MV Instrument Transformers for Power Quality Measurement: the contribution from the IT4PQ project
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F24%3AN0000005" target="_blank" >RIV/00177016:_____/24:N0000005 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/10645830" target="_blank" >https://ieeexplore.ieee.org/document/10645830</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/CPEM61406.2024.10645830" target="_blank" >10.1109/CPEM61406.2024.10645830</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Characterization of MV Instrument Transformers for Power Quality Measurement: the contribution from the IT4PQ project
Popis výsledku v původním jazyce
Power Quality (PQ) monitoring in electrical transmission and distribution grids relies on the accurate measurement of wideband high voltages and high currents. Ensuring traceability of the measurements carried out is generally only partially accomplished by calibration of the low voltage (LV) PQ measurement instrument, whereas the calibration of the instrument transformer (IT) is mostly limited to the power frequency or performed at LV. In the paper, objectives and main outputs of the research project “Measurement methods and test procedures for assessing accuracy of Instrument Transformers for Power Quality measurements” (IT4PQ), which is focused on medium voltage (MV) grids, are outlined. An overview of the metrological framework developed within IT4PQ is given, together with details of the characterization of different types of MV ITs, both under controlled laboratory conditions and in the presence of influence parameters. Laboratory calibration measurement uncertainty is within a few hundreds of ppm and microradian up to 9 kHz, for ratio and phase errors respectively.
Název v anglickém jazyce
Characterization of MV Instrument Transformers for Power Quality Measurement: the contribution from the IT4PQ project
Popis výsledku anglicky
Power Quality (PQ) monitoring in electrical transmission and distribution grids relies on the accurate measurement of wideband high voltages and high currents. Ensuring traceability of the measurements carried out is generally only partially accomplished by calibration of the low voltage (LV) PQ measurement instrument, whereas the calibration of the instrument transformer (IT) is mostly limited to the power frequency or performed at LV. In the paper, objectives and main outputs of the research project “Measurement methods and test procedures for assessing accuracy of Instrument Transformers for Power Quality measurements” (IT4PQ), which is focused on medium voltage (MV) grids, are outlined. An overview of the metrological framework developed within IT4PQ is given, together with details of the characterization of different types of MV ITs, both under controlled laboratory conditions and in the presence of influence parameters. Laboratory calibration measurement uncertainty is within a few hundreds of ppm and microradian up to 9 kHz, for ratio and phase errors respectively.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/8B20011" target="_blank" >8B20011: Measurement methods and test procedures for assesing accuracy of instruments transformers for power quality measurements</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2024 Conference on Precision Electromagnetic Measurements (CPEM)
ISBN
979-8-3503-6104-9
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
—
Místo vydání
Denver, CO, USA
Místo konání akce
Denver, CO, USA
Datum konání akce
1. 1. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
001308252300005