The paper describes a bilateral comparison of a set of planar multijunction thermal converters (PMJTC) maintained at the Czech Metrology Institute (CMI) and the Silesian University of Technology (SUT), Poland, at 1 V and selected frequencies from 10 Hz to 1 MHz. The comparison shows good agreement among the AC-DC transfer differences of SUT and CMI standards. The analysis shows that above approximately 700 kHz, the SUT and CMI standards differ in their AC-DC voltage transfer differences, but these differences, below 5 µV/V, are still within measurement uncertainties. The result was based on an international visit from CMI to SUT.
Název v anglickém jazyce
Bilateral comparison of planar multijunction thermal converters maintained at CMI and SUT
Popis výsledku anglicky
The paper describes a bilateral comparison of a set of planar multijunction thermal converters (PMJTC) maintained at the Czech Metrology Institute (CMI) and the Silesian University of Technology (SUT), Poland, at 1 V and selected frequencies from 10 Hz to 1 MHz. The comparison shows good agreement among the AC-DC transfer differences of SUT and CMI standards. The analysis shows that above approximately 700 kHz, the SUT and CMI standards differ in their AC-DC voltage transfer differences, but these differences, below 5 µV/V, are still within measurement uncertainties. The result was based on an international visit from CMI to SUT.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2024 Conference on Precision Electromagnetic Measurements (CPEM)
ISBN
—
ISSN
2160-0171
e-ISSN
—
Počet stran výsledku
2
Strana od-do
1-2
Název nakladatele
—
Místo vydání
—
Místo konání akce
Denver, Colorado, USA
Datum konání akce
8. 7. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
001308252300068