Posouzení mikrocirkulace svalu a střeva u potkana
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F08%3A00001098" target="_blank" >RIV/00179906:_____/08:00001098 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11150/08:00106758
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Non invasive in vivo assessment of the skeletal muscle and small intestine serous surface microcirculation in rat : sidestream dark-field (SDF) imaging
Popis výsledku v původním jazyce
The pathophysiology of microcirculation is intensively investigated to understand disease development at the microscopic level. The goal of this experimental study was to describe basic microcirculatory parameters of skeletal muscle and ileal serous surface microcirculation in the rat using SDF imaging and to standardize the technical aspects of the protocol. There was no statistically significant difference in mean values of FCD obtained from the muscle (P = 0.273) in contrast to ileal serous surface where the difference was statistically significant (P = 0.036). Neither on the muscle surface (P = 0.739) nor on ileal serous surface (P = 0.659) statistically significant differences in small vessels percentage was detected. Our study has shown that SDFimaging represents promising technology for experimental and clinical studies.
Název v anglickém jazyce
Non invasive in vivo assessment of the skeletal muscle and small intestine serous surface microcirculation in rat : sidestream dark-field (SDF) imaging
Popis výsledku anglicky
The pathophysiology of microcirculation is intensively investigated to understand disease development at the microscopic level. The goal of this experimental study was to describe basic microcirculatory parameters of skeletal muscle and ileal serous surface microcirculation in the rat using SDF imaging and to standardize the technical aspects of the protocol. There was no statistically significant difference in mean values of FCD obtained from the muscle (P = 0.273) in contrast to ileal serous surface where the difference was statistically significant (P = 0.036). Neither on the muscle surface (P = 0.739) nor on ileal serous surface (P = 0.659) statistically significant differences in small vessels percentage was detected. Our study has shown that SDFimaging represents promising technology for experimental and clinical studies.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FE - Ostatní obory vnitřního lékařství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Research
ISSN
0862-8408
e-ISSN
—
Svazek periodika
57
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
—
Kód UT WoS článku
000257270900006
EID výsledku v databázi Scopus
—